Victron VE.Can RJ45 Terminator Bag of 2 | ASS030700000
- Vendor
- Victron Energy
- SKU
- ASS030700000
- Availability
- In stock
- Weight
- 0.009 kg
Was£6.42£5.35Save £0.76Save £0.63
£5.66inc VAT £4.72exc VAT
Product Description
The Victron VE.Can RJ45 terminator is a passive network component used to correctly terminate a VE.Can bus. Sold as a bag of two, it suits installers setting up Victron systems where several devices share a single VE.Can network.
Key features
- Function, terminates a VE.Can network bus at both ends to prevent signal reflection and communication errors.
- Connector, RJ45 form factor, fits directly into the VE.Can port on compatible Victron devices.
- Power, passive component, no power or configuration needed.
- Pack size, bag of two, giving both terminators required for one VE.Can network segment.
- Weight, 8 g per bag.
- Compatibility, works with Victron devices using the VE.Can interface, including Quattro, Multi, MPPT charge controllers and Cerbo GX.
Product overview
A CAN bus network needs termination at each end to function correctly. Without it, signal reflections can cause unreliable data, fault conditions or loss of communication between devices such as inverter/chargers, MPPT controllers and the GX device. This terminator plugs directly into a spare VE.Can RJ45 port to provide that termination.
Each VE.Can segment needs exactly two terminators, one at each physical end of the bus. This bag supplies both for a single segment. Larger systems with multiple segments will need additional bags.
Applications
- Terminating VE.Can networks in off-grid solar installations using Victron equipment.
- Completing CAN bus wiring in marine and vehicle installations with multiple Victron devices.
- Commercial and industrial Victron systems where several devices share a single VE.Can bus.
- Replacing lost or damaged terminators in an existing installation.
What's in the box
- 2 x VE.Can RJ45 terminator plugs
Installation notes
Fit one terminator into the unused VE.Can port on each of the first and last devices in the network chain. Devices in the middle should have both VE.Can ports occupied by network cables, not terminators. Incorrect termination is a common cause of VE.Can communication issues, so check placement if devices are not appearing correctly on the GX device or VRM portal. No tools are required.
More in Victron Miscellaneous
Victron Galvanic Isolator VDI-64A Shore Power Protection£246.73inc VAT
£205.61exc VAT
Victron RJ45 UTP Cable 20m£26.76inc VAT
£22.30exc VAT
Victron Isolation Transformer 2500W 115/230V£307.64inc VAT
£256.37exc VAT
Victron Splitter Cord CEE Plug to 2x CEE Coupling 16A/250V£65.09inc VAT
£54.24exc VAT
Victron RJ45 Splitter 1x Male 2x Female 15cm Cable£16.04inc VAT
£13.37exc VAT
Victron RS232 to USB Serial Converter£23.93inc VAT
£19.94exc VAT