£888.29inc VAT £740.24exc VAT
Delivery from £35.00 to mainland UK Sent on a pallet, booked in with you first. Or collect free from Coventry.All delivery costs
Product Description
The Victron MultiPlus-II 48/6k5/100-50 230V GX is a combined inverter, battery charger and automatic transfer switch with a GX controller built into the same enclosure. It runs from a 48V battery bank and puts out 6,000VA of continuous inverter power at 230V AC, and because the GX device is already inside the case there is no need to wire in a separate Cerbo GX or Color Control unit.
Key features of the victron multiplus ii 6k5 gx
- Inverter output, 6,000VA continuous, 48V DC input.
- Integrated GX controller, built-in monitoring, VRM portal connectivity and DVCC, no extra hardware.
- Battery charger, 100A with adaptive charging, supports lithium and lead-acid chemistries.
- AC input limit, 50A on shore or generator input, with PowerControl and PowerAssist to avoid overloading the source.
- Transfer switch, typical switchover of 20ms, keeps connected loads live through a grid or generator interruption.
- Output, single-phase 230V, suitable for standard UK and European AC distribution.
Product overview
Because the MultiPlus-II GX houses the inverter charger and the GX device together, the unit connects straight to the VRM portal over Ethernet or Wi-Fi, logs system data and talks to compatible BMS units and MPPT charge controllers over VE.Direct and VE.Can. That cuts down on wiring and cabinet space on residential and light commercial jobs.
The 100A charger uses a three-stage adaptive algorithm, configurable for LFP, gel, AGM and other battery types through VictronConnect or the GX interface. Paired with the 50A AC input limit, PowerAssist lets the unit top up a limited AC source, a small generator for example, with battery power once the load exceeds what that source can deliver alone. That suits off-grid cabins, boats or sites where generator capacity is tight.
Parallel operation is supported for extra capacity, and three-phase output is possible with two additional MultiPlus-II units. ESS configuration is available for grid-connected sites needing self-consumption optimisation or backup. Whether a UK grid-tied install needs G98 or G99 sign-off depends on the specific system and DNO approval.
Applications
- Off-grid homes and rural properties needing a high-capacity inverter charger with monitoring already built in.
- Hybrid solar systems combining grid or generator input with battery storage and MPPT charge controllers.
- ESS installations for self-consumption and grid backup in domestic or light commercial settings.
- Marine and vehicle systems using a 48V battery bank with 230V AC output and remote monitoring.
- Generator-backed sites where AC input needs to be capped and supplemented by battery power.
Technical Specifications 51 rows Show
Technical specifications (48/6k5/100-50)
| Model | MultiPlus II GX 230V 48/6k5/100-50 |
| PowerControl and PowerAssist | Yes |
| Transfer switch | 50 A |
| Maximum AC input current | 50 A |
| INVERTER | |
| DC input voltage range | 38 to 60 V |
| Output | 230 V ±2% | 50 Hz ±0.1% |
| Continuous output power at 25°C | 6 kW |
| Continuous output power at 40°C | 5.7 kW |
| Continuous output power at 65°C | 4.6 kW |
| Time limited power 1 (cold start) | 6.5 kW for 4 hours |
| Time limited power 2 (cold start) | 8 kW for 1 hour |
| Max apparent feed in power | 6 kW |
| Peak power | 11 kW for 1 minute |
| Maximum efficiency | 96% |
| Zero load power | 28 W |
| Zero load power in AES mode | 18 W |
| Zero load power in Search mode | 8 W |
| CHARGER | |
| AC input voltage range | 187 to 265 V |
| AC input frequency range | 45 to 65 Hz |
| Charge voltage (absorption) | 57.6 V |
| Charge voltage (float) | 55.2 V |
| Storage mode voltage | 52.8 V |
| Max battery charge current at 25°C | 100 A |
| Max battery charge current at 40°C | 95 A |
| Battery temperature sensor | Yes |
| Compatible battery chemistries | Lithium, Lead acid, Zinc Bromine and more |
| GENERAL | |
| Auxiliary output | Yes (32 A) |
| Interfaces | BMS CAN, USB, Ethernet, VE.Direct, WiFi |
| External AC current sensor (optional) | 50 A or 100 A |
| Programmable relay | Yes |
| VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
| General purpose communication ports | Yes, 2x |
| Remote on off | Yes |
| Operating temperature range | -40°C to +65°C (fan assisted cooling) |
| Maximum humidity (non condensing) | 95% |
| Maximum altitude | 2000 m |
| ENCLOSURE | |
| Material and colour | Steel, blue RAL 5012 |
| Protection category | IP21 |
| Battery connection | M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 29 kg |
| Dimensions (h x w x d) | 644 x 320 x 150 mm |
| STANDARDS | |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission and immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
| Uninterruptible power supply | Certification pending |
| Anti islanding | Certification pending |
Manufacturer datasheet. Figures as published by the manufacturer.
More in Victron Inverter Chargers
Victron MultiPlus-II 48/6k5/100-50 230V Inverter Charger£786.44inc VAT
£655.37exc VAT
Victron MultiPlus-II 48/3000/35-32 230V GX Inverter Charger£572.24inc VAT
£476.87exc VAT
Victron MultiPlus-II 24/3000/70-32 Inverter Charger 230V£719.24inc VAT
£599.37exc VAT
Victron MultiPlus 12/3000/120-50 Inverter Charger 230V£1,100.39inc VAT
£916.99exc VAT
Victron Quattro 24/8000/200-100/100 Inverter Charger 230V£2,091.59inc VAT
£1,742.99exc VAT
Victron MultiPlus 24/500/10-16 230V VE.Bus Inverter Charger£265.64inc VAT
£221.37exc VAT