Current transformer with 5 meter black cable, red and gray wire leads, and blue clamp labeled SCT013 100A:50mA.

Victron Current Transformer 100A:50mA MultiPlus-II 5m Wire-End | CTR120000550

£23.09
Skip to product information
Current transformer with 5 meter black cable, red and gray wire leads, and blue clamp labeled SCT013 100A:50mA.

Victron Current Transformer 100A:50mA MultiPlus-II 5m Wire-End | CTR120000550

Vendor
Victron Energy
SKU
CTR120000550
Availability
In stock
Weight
0.095 kg

£23.09inc VAT £19.24exc VAT

Secure checkout
Payment methods
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Product Description

This current transformer measures AC current up to 100A for use with the Victron MultiPlus-II inverter/charger. It outputs a 50mA signal on a 5-metre wire-end lead, so it can be fitted at the measurement point and wired straight into the monitoring circuit without extra connectors.

Key features

  • Ratio, 100A primary to 50mA secondary output.
  • Cable length, 5 metres, giving flexibility when positioning the transformer relative to the MultiPlus-II.
  • Termination, wire-end, connects directly to the MultiPlus-II current sensing input.
  • Design, clip-on split-core or solid-core construction for fitting around a single conductor.
  • Weight, 85g, easy to mount in a distribution board or enclosure.
  • Compatibility, specific to the Victron MultiPlus-II series.

How it works with the MultiPlus-II

The MultiPlus-II uses current transformer inputs to monitor AC current on the grid or generator connection. That reading is what allows functions such as PowerControl and PowerAssist to work, since the unit needs to know how much current is already being drawn before it decides how much to add or limit. The 100A:50mA ratio matches the MultiPlus-II's input specification, and the 5-metre lead gives enough reach to route the cable from the measurement point, typically the incoming live conductor at the consumer unit or distribution board, back to the MultiPlus-II terminals.

Applications

  • PowerControl and PowerAssist current monitoring on MultiPlus-II installations.
  • Grid current measurement in hybrid solar systems using the MultiPlus-II.
  • Generator current monitoring where the MultiPlus-II manages generator load.
  • Retrofit installations where a current transformer is missing or needs replacing.

What's in the box

  • 1 x Current Transformer 100A:50mA with 5-metre wire-end cable

Installation notes

Fitting must be done by a qualified electrician, following safe isolation procedures and BS 7671 wiring regulations. Grid-connected MultiPlus-II systems must also meet G98 or G99 requirements where applicable. Connect the CT to the correct terminals as set out in the Victron wiring documentation, and fit it around a single conductor only, never around a bundled twin-and-earth or multi-conductor cable.