Blue current transformer clamp with 10-meter black lead wire, two stripped wire ends, labeled SCT013 100A:50mA.

Victron Current Transformer 400A:50mA 10m Wire-End | CTR140050100

£33.59
Skip to product information
Blue current transformer clamp with 10-meter black lead wire, two stripped wire ends, labeled SCT013 100A:50mA.

Victron Current Transformer 400A:50mA 10m Wire-End | CTR140050100

Vendor
Victron Energy
SKU
CTR140050100
Availability
In stock
Weight
0.3 kg

£33.59inc VAT £27.99exc VAT

Secure checkout
Payment methods
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Product Description

This current transformer measures AC current for the Victron MultiPlus-II inverter/charger, producing a 50mA secondary signal from a 400A primary load. It connects via a 10-metre wire-end cable, giving installers room to position the metering point away from the inverter itself.

Key features

  • Ratio, 400A:50mA for current sensing across the load range.
  • Cable length, 10 metres, wire-end termination.
  • Weight, 0.25 kg.
  • Compatibility, designed for use with the Victron MultiPlus-II inverter/charger range.
  • Design, clips around an existing conductor without breaking the circuit.

Why it matters for ESS installations

The MultiPlus-II uses this signal to monitor grid import and export in real time, which is what allows correct power assist, grid feed-in control and ESS charge/discharge management. Without accurate current data at the CT input, the inverter cannot manage these functions properly.

Cable length in practice

A 10-metre run means the metering point can sit some distance from the inverter or GX device without a field-spliced extension, which can introduce errors into the signal. The wire-end format connects straight to the designated terminal on the MultiPlus-II.

Installation notes

Fit this by a qualified electrician familiar with MultiPlus-II and ESS setup. The CT clips around the correct conductor, usually the grid live feed, and must be oriented as specified in the MultiPlus-II manual; the wrong orientation reverses the current reading. Do not install around bundled or multi-core cable containing more than one current-carrying conductor. UK grid-connected ESS installations must meet G98 or G99 requirements as applicable.

What's in the box

  • 1 x Current Transformer 400A:50mA with 10-metre wire-end cable