Product Description
The Victron SmartSolar MPPT 250/100-MC4 VE.Can is a solar charge controller built for large off-grid, marine and commercial systems. It accepts a maximum PV open-circuit voltage of 250V and delivers up to 100A of charge current, with MC4 connectors built into the unit and a VE.Can interface for network integration.
Victron SmartSolar MPPT 250/100 key features
- PV input and charge current: maximum PV open-circuit voltage of 250V and maximum charge current of 100A, suited to large battery banks and high-output PV arrays.
- MC4 connectors: integrated for direct connection to standard solar panel strings without extra adaptors.
- VE.Can networking: connects with other VE.Can-compatible Victron devices such as the Cerbo GX.
- Bluetooth monitoring: built-in Bluetooth works with the VictronConnect app for wireless monitoring, configuration and firmware updates.
- Battery compatibility: configurable charge profiles for lithium, AGM, gel and flooded batteries.
- Load management: supports load output control and a battery life algorithm for off-grid systems.
Applications
This controller suits large off-grid solar systems on 24V or 48V battery banks that need high charge current. It also works in marine and narrowboat installations where MC4 connection and network integration matter, and in commercial or agricultural off-grid sites using Victron GX monitoring and VRM remote management. Multiple SmartSolar units can be networked together via VE.Can for coordinated charging across a larger system, and it can form part of a hybrid setup with solar, generator and inverter-charger inputs managed through a Victron GX device.
What's in the box
- Victron SmartSolar MPPT 250/100-MC4 VE.Can charge controller (SCC125110512)
Technical Specifications 37 rows Show
| Parameter | Value |
|---|---|
| Model | SmartSolar MPPT 250/100-Tr VE.Can |
| Part Number | SCC125110512 |
| Battery System Voltage | 12 / 24 / 48 V auto select (36 V manual) |
| Charge Current Rating | 100 A |
| PV Array Power at 12V | 1450 W |
| PV Array Power at 24V | 2900 W |
| PV Array Power at 36V | 4350 W |
| PV Array Power at 48V | 5800 W |
| Maximum PV Short-Circuit Current | 70 A (max 30 A per MC4 connector) |
| Absolute Maximum PV Open-Circuit Voltage | 250 V (coldest conditions) |
| PV Start-up and Operating Maximum Voltage | 245 V |
| Peak Efficiency | 99 % |
| Standby Power Draw | Less than 35 mA at 12 V / 20 mA at 48 V |
| Absorption Voltage (default) | 14.4 / 28.8 / 43.2 / 57.6 V (adjustable) |
| Float Voltage (default) | 13.8 / 27.6 / 41.4 / 55.2 V (adjustable) |
| Equalisation Voltage (default) | 16.2 / 32.4 / 48.6 / 64.8 V (adjustable) |
| Charging Algorithm | Multi-stage adaptive (8 pre-programmed) or user defined |
| Temperature Compensation Rate | -16 mV / -32 mV / -64 mV per °C |
| Protection Features | PV reverse polarity / Output short circuit / Over temperature |
| Operating Temperature Range | -30 to +60 °C (full rated output up to 40 °C) |
| Humidity Tolerance | 95 %, non-condensing |
| Maximum Operating Altitude | 5000 m (full rated output up to 2000 m) |
| Environmental Rating | Indoor, unconditioned |
| Pollution Degree | PD3 |
| Communication Interfaces | VE.Can, VE.Direct and Bluetooth |
| Remote On/Off Function | Yes (2 pole connector) |
| Programmable Relay Specification | DPST. AC: 240 VAC / 4 A. DC: 4 A up to 35 VDC, 1 A up to 60 VDC |
| Parallel Operation Capability | Yes, synchronised with VE.Can (max 25 units) or Bluetooth (max 10 units) |
| Enclosure Colour | Blue (RAL 5012) |
| PV Terminal Size | 35 mm² / AWG2 |
| Battery Terminal Size | 35 mm² / AWG2 |
| Ingress Protection Rating | IP43 (electronic components), IP22 (connection area) |
| Weight | 4.5 kg |
| Dimensions (H x W x D) | 216 x 295 x 103 mm |
| Safety Standards | EN/IEC 62109-1, UL 1741, CSA C22.2 |
| Data Logging Parameters | Battery voltage, current, temperature, load output current, PV voltage, PV current |
| Data Storage Duration | 46 |
If more PV power is connected, the controller will limit input power. PV voltage must exceed Vbat + 5 V to start, and the minimum PV voltage thereafter is Vbat + 1 V. A PV array with a higher short-circuit current may damage the controller.
Manufacturer datasheet. Figures as published by the manufacturer.
More in Victron Solar Chargers
Victron SmartSolar MPPT 250/60-MC4 Solar Charge Controller£307.61inc VAT
£256.34exc VAT
Victron SmartSolar MPPT 250/70-MC4 VE.Can Charge Controller£383.97inc VAT
£319.98exc VAT
Victron BlueSolar MPPT 150/100-Tr VE.Can Solar Charge Controller£379.49inc VAT
£316.24exc VAT
Victron MPPT WireBox-S 100-15 Terminal Cover£18.18inc VAT
£15.15exc VAT
Victron Temperature Sensor for BlueSolar PWM-Pro Charge Controller£8.82inc VAT
£7.35exc VAT
Victron MPPT WireBox-XL Tr 150-85/100 & 250-85/100 VE.Can£25.98inc VAT
£21.65exc VAT