Victron Power Inverter 48/1600 230V VE.Direct SCHUKO | PIN482161200
- Vendor
- Victron Energy
- SKU
- PIN482161200
- Availability
- In stock
- Weight
- 8.0 kg
€278,95inc VAT €232,46exc VAT
Delivery from £10.00 to mainland UK 3 to 5 working days. Or collect free from Coventry.All delivery costs
Product Description
The Victron Inverter 48/1600 takes power from a 48 V battery bank and turns it into 230 V 50 Hz AC. Continuous output is 1,450 W at 25 °C, with 2,100 W available at peak. Loads plug straight into the built-in Schuko (CEE 7/4) socket, and a VE.Direct port handles monitoring and setup.
Victron power inverter key features
- Output: 1,450 W continuous at 25 °C, 1,300 W at 40 °C, 2,100 W peak
- Battery input: 48 V nominal, DC input range 36.8 V to 62 V
- Eco mode: zero load draw falls from 15 W to 3 W, with a 2.5 s retry interval and an adjustable stop and start power setting
- Battery protection: low shutdown at 37.2 V, restart and alarm at 43.6 V, plus dynamic low DC shutdown
- Control: VE.Direct port, fully programmable settings and a two pole screw terminal for remote on/off
- Efficiency: 92 % maximum
Sizing and installation
This is a stand alone battery inverter for 230 V AC loads. Output drops as the unit gets warmer: 1,450 W at 25 °C becomes 1,300 W at 40 °C. Fitting it in a warm cabinet, plant room or vehicle compartment? Size your load against the lower figure. The 2,100 W peak rating handles brief inrush from motors, compressors and power tools.
Standby draw on battery systems
With nothing connected the inverter uses 15 W. Eco mode brings that down to 3 W. It checks for demand every 2.5 s and switches to full output once the load passes your chosen threshold, so set it just below the smallest device you plan to run, phone chargers included.
Protection and operating range
Built-in protection covers output short circuit, overload, high and low battery voltage, over temperature and excessive DC ripple. Dynamic low DC shutdown takes load into account, which stops voltage sag under heavy draw from tripping the inverter early. Thresholds can be adjusted over VE.Direct to match your battery chemistry, and the battery charged detection voltage is 56 V.
The rated operating range runs from minus 40 °C to plus 65 °C at up to 95 % humidity. Please note the AC outlet is a Schuko (CEE 7/4) socket, not a UK BS 1363 socket.
More in Victron Inverters
Victron Phoenix Inverter 48/3000 230V Smart€523,95inc VAT
€436,63exc VAT
Victron Phoenix Inverter 12/1600 230V VE.Direct SCHUKO€272,95inc VAT
€227,46exc VAT
Victron Power Inverter 48/1600 230V VE.Direct UK Socket€278,95inc VAT
€232,46exc VAT
Victron Power Inverter 48/1600 230V VE.Direct IEC€278,95inc VAT
€232,46exc VAT
Victron Power Inverter 24/250 230V VE.Direct SCHUKO€79,95inc VAT
€66,63exc VAT
Victron Power Inverter 24/1600 230V VE.Direct UK Socket€278,95inc VAT
€232,46exc VAT