Solar DC Isolator Switch 2 String 1000V | Kraus & Naimer KGD40B TD108/D-P004 KL11V
- Vendor
- Kraus & Naimer
- SKU
- 003289
- Availability
- In stock
- Weight
- 0.5 kg
€155,95inc VAT €129,96exc VAT
Delivery from £4.99 to mainland UK 3 to 5 working days. Or collect free from Coventry.All delivery costs
Product Description
Two PV strings, one rotary handle. The Kraus & Naimer KGD40B TD108/D-P004 KL11V is a solar DC switch disconnector that isolates two independent strings in a single action, so a dual MPPT inverter needs only one isolator on the wall. That means one enclosure to fix, fewer cable runs and less time on site.
Solar DC isolator switch features
- Configuration: 2 x 2 pole, switching the positive and negative of each string
- Utilisation category: DC-21B to IEC 60947-3
- Per string ratings: 50A at 400V up to 30A at 1000V DC
- Enclosure: IP66/IP67 for indoor and outdoor installation, UL94 V-0 flame retardant
- Marking: CE
- Operation: clear OFF and ON positions on the front plate, knockouts for cable gland entry
Ratings per string
| DC voltage | Current per string |
|---|---|
| 400V | 50A |
| 500V | 50A |
| 660V | 40A |
| 800V | 40A |
| 1000V | 30A |
Where it fits
Most string and hybrid inverters carry two MPPT inputs. Instead of doubling up on hardware, this unit handles both strings while keeping them electrically separate, each with its own positive and negative path through the switch. It suits dual MPPT grid tied and hybrid string inverters, residential rooftop systems with two strings and commercial arrays running two strings per inverter.
BS 7671 requires a means of isolating the DC side of a PV inverter for safe maintenance. This switch covers both strings at once. The contacts are factory linked to achieve the published ratings, and those ratings are not valid if the links are removed.
Installation and safety
PV modules produce dangerous DC voltage whenever light falls on them and cannot be switched off at source. Fitting must be carried out by a qualified electrician or MCS certified installer in line with BS 7671.
- Check string open circuit voltage at the lowest expected temperature, and string current, against the rating used.
- Leave the factory links in place.
- Use correctly sized PV cable, suitable glands and correct polarity on each string.
- Keep string 1 and string 2 separate. Never cross connect them.
- Do not open the enclosure while the strings are connected.
In the box
- 1 x Kraus & Naimer KGD40B TD108/D-P004 KL11V 2 string DC switch disconnector, fitted in an IP66/67 enclosure
More in AC & DC Protection
Automatic ATS Transfer Switch 63A 2 Pole€74,95inc VAT
€62,46exc VAT
63A 2-Pole Manual Changeover Switch IP66/67€78,95inc VAT
€65,79exc VAT
DC Isolator 63A 2-Pole 600V Din RailFrom€28,95inc VAT
€24,13exc VAT
63A 4-Pole DC Isolator 1200VFrom€28,95inc VAT
€24,13exc VAT
AC Isolator Switch 4-Pole 230V-440V 63A IP65€34,95inc VAT
€29,13exc VAT
DC MCCB Circuit Breaker 500V 2-Pole for Solar PV & BatteriesFrom€117,95inc VAT
€98,29exc VAT