All Three-Phase Hybrid Inverters
Solis white hybrid solar inverter with touchscreen display, mounting brackets, and five cable connectors at base, product sho

Solis 125kW Three Phase Hybrid Solar Inverter High Voltage | S6-EH3P125K10-NV-YD-H

€9.517,95
Skip to product information
Solis white hybrid solar inverter with touchscreen display, mounting brackets, and five cable connectors at base, product sho

Solis 125kW Three Phase Hybrid Solar Inverter High Voltage | S6-EH3P125K10-NV-YD-H

Vendor
Solis
SKU
003102
Availability
In stock
Weight
170.0 kg

€9.517,95inc VAT €7.931,63exc VAT

Delivery from £120.00 to mainland UK Sent on a pallet, booked in with you first. Or collect free from Coventry.All delivery costs

Secure checkout
Payment methods
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Product Description

The Solis S6-EH3P125K10-NV-YD-H is a 125kW three phase hybrid solar inverter built for high voltage battery storage. It sits at the top of the Solis Solarator 80 to 125K series and brings solar, storage, grid and generator inputs together behind a single control point, aimed at commercial and industrial sites where an outage is expensive.

Three phase hybrid solar inverter features

  • Solar input: recommended PV array up to 250kW, maximum input voltage 1000V, MPPT range 150V to 950V across 10 trackers and 20 strings, each input rated at 42A.
  • Battery ports: two independent high voltage battery ports from 300V to 950V, each with its own BMS connection, charging or discharging at up to 100A per port for up to 200A combined.
  • Backup switching: under 10ms transfer from grid to off-grid for a single unit, with 140% of rated power for 10 seconds and 160% for 200 milliseconds to help start motors and pumps.
  • Parallel operation: multiple units run together up to 1.25MW, with switchover below 20ms in a parallel system of up to 6 inverters, and each phase carrying up to 33% of rated power.
  • Monitoring: 7 inch LCD, Bluetooth and the Solis app for local setup, with Wi-Fi, LAN and Bluetooth built in and 4G optional.
  • Enclosure: IP66 rated with intelligent redundant fan cooling, operating from -25°C to +60°C and up to 3000m altitude.

Battery and generator support

Solis rates the battery range for modules from 100Ah to 314Ah, communicating over CAN. A dedicated 125kW generator input, weak grid control and a utility bypass keep loads running when supply is unreliable. Solar and storage work together for export limiting and dynamic reactive power compensation, and the inverter supports both DC and AC coupling with a three in one interface for on-grid PV, wind power and diesel generators.

Applications

Suited to factories, large farms, distribution centres, cold stores and other commercial sites needing peak demand reduction, export limiting or backup for critical loads, including sites with a weak grid connection or a standby generator.

Installation notes

This is a high voltage battery inverter for compatible lithium systems between 300V and 950V; it is not suitable for 48V battery banks. Solis lists G99 among planned grid connection standards for this range, so confirm certification status before specifying it for a UK grid connection. Installation and commissioning must be carried out by a qualified installer with correct DC fusing, AC protection, surge protection and earthing. The unit weighs 170kg and measures 1174 x 814 x 400mm.

Technical Specifications 85 rows Show

Model Information

ParameterValue
ModelS6-EH3P125K10-NV-YD-H
SeriesSolis S6 Solarator 80 to 125K
Inverter TypeThree Phase High Voltage Hybrid Energy Storage Inverter
Rated Power125kW

Input DC (PV Side)

ParameterValue
Recommended Maximum PV Array Size250kW
Maximum Usable PV Input Power250kW
Maximum Input Voltage1000V
Rated Voltage600V
Start-up Voltage180V
MPPT Voltage Range150V to 950V
Maximum Input Current10 x 42A
Maximum Current per DC Input42A
Maximum Short Circuit Current10 x 60A
MPPT Number / Maximum Input Strings10 / 20

Battery

ParameterValue
Battery TypeLi-ion (high voltage)
Battery Voltage Range300V to 950V
Battery Ports / BMS Ports2 / 2
Maximum Charge / Discharge Current100A x 2 / 100A x 2
Maximum Charge / Discharge Current per Port100A
CommunicationCAN

Output AC (Grid Side)

ParameterValue
Rated Output Power125kW
Maximum Apparent Output Power125kVA
Rated Grid Voltage3/N/PE, 220V / 380V, 230V / 400V
Rated Grid Frequency50Hz / 60Hz
Rated Grid Output Current189.9A / 180.4A
Power Factor>0.99 (0.8 leading to 0.8 lagging)
THDi<3%

Input AC (Grid Side)

ParameterValue
Maximum Input Power164.5kW / 173.2kW
Input Voltage Range304V to 460V
Maximum Input Current250A

Output AC (Backup)

ParameterValue
Rated Output Power125kW
Maximum Apparent Output Power1.4 x rated power for 10s, 1.6 x rated power for 200ms
Backup Switch Time<10ms single unit, <20ms parallel (up to 6 units)
Rated Output Voltage3/N/PE, 220V / 380V, 230V / 400V
Rated Frequency50Hz / 60Hz
Rated Output Current189.9A / 180.4A
Maximum AC Passthrough Current189.9A / 180.4A
THDv at Linear Load<3%

Input AC (Generator Side)

ParameterValue
Maximum Input Power125kW
Rated Input Current189.9A / 180.4A
Rated Input Voltage3/N/PE, 220V / 380V, 230V / 400V
Rated Input Frequency50Hz / 60Hz

Efficiency

ParameterValue
Maximum Efficiency97.5%
EU Efficiency97.2%
Battery Charged by PV / AC Maximum Efficiency98.2% / 97.0%
Battery Discharge Efficiency97.0%

Protection

ParameterValue
Surge ProtectionDC Type II / AC Type II
Output Over Current ProtectionYes
Insulation Resistance MonitoringYes
Residual Current DetectionYes
Integrated PV SwitchYes
DC Reverse Polarity ProtectionYes
Anti-islanding ProtectionYes
Protection Class / Overvoltage CategoryI / DC II, AC III
Integrated AFCI 2.0Optional

General Data

ParameterValue
Maximum Power per Phase (Grid and Backup)33% of rated power
Dimensions W x H x D1174 x 814 x 400mm
Weight170kg
TopologyNon-isolated
Self-consumption<45W
Operating Temperature Range-25°C to +60°C
Relative Humidity0 to 100%
IP RatingIP66
CoolingIntelligent redundant fan cooling
Maximum Operating Altitude3000m
Grid Connection StandardG99, VDE-AR-N 4105, EN 50549-1/-2/-10, IEC 62116, IEC 61727 and others (listed by Solis as planned, confirm status before specifying)
Safety / EMC StandardIEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011

Features

ParameterValue
PV ConnectionMC4 connector
Battery ConnectionTerminal connector
AC ConnectionTerminal block
Display7.0 inch LCD, Bluetooth and app
CommunicationWi-Fi, LAN, Bluetooth, CAN-BMS x2, CAN-Parallel x2, RS485-Meter, RS485, DRM, DI x5, DO x4; 4G optional
Parallel OperationUp to 1.25MW (Solis STS cabinet recommended above 6 units)
Supplied WithCT or meter