{"product_id":"victron-multiplus-ii-5000va-charger","title":"Victron MultiPlus-II 48\/5000\/70-50 Inverter Charger 230V | PMP482505012","description":"\u003cp\u003eThe Victron MultiPlus-II 48\/5000\/70-50 230V (PMP482505012) is a 5000VA inverter charger built around a 48V battery bank. It combines a pure sine wave inverter, a 70A battery charger and an automatic transfer switch in one unit, delivering 230V AC output for off-grid, backup and solar storage installations.\u003c\/p\u003e\u003ch2\u003eBattery charger with inverter for 48V systems\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter output\u003c\/strong\u003e, 5000VA continuous, 48V DC input, 230V AC pure sine wave output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery charger\u003c\/strong\u003e, 70A output with adaptive charge management for lead-acid and lithium batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input limit\u003c\/strong\u003e, 50A, with PowerControl and PowerAssist to avoid overloading a generator or shore power feed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer switch\u003c\/strong\u003e, automatic changeover between mains and inverter output in less than 20ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel and three-phase\u003c\/strong\u003e, multiple units can be combined for higher power or three-phase systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e, VE.Bus for monitoring and configuration via VictronConnect or Venus OS, plus a programmable relay and two-signal BMS connection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePowerAssist and PowerControl\u003c\/h2\u003e\u003cp\u003ePowerAssist draws extra current from the battery when load exceeds what a limited AC source, such as a generator or shore power connection, can supply on its own. This stops a generator overloading or a shore breaker tripping in marine, vehicle or remote site setups. PowerControl works the other way, capping AC input draw at a set limit and sending any spare capacity to charging.\u003c\/p\u003e\u003cp\u003eUp to six units can run in parallel for a maximum of 30kVA, or three units per phase for a three-phase configuration, useful on larger off-grid or commercial sites. Configuration and firmware updates go through VE.Bus, using a GX device or an MK3-USB interface.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003ePMP482505012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Output Power\u003c\/td\u003e\n\u003ctd\u003e5000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage (Nominal)\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger Output\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Current Limit\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Switch Time\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eVE.Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\u003ctd\u003eUp to 6 units (max 30kVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle phase or three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e8719076058366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOff-grid residential and commercial solar installations with 48V battery banks.\u003c\/li\u003e\n\u003cli\u003eHybrid solar systems needing both generator or grid charging and battery backup.\u003c\/li\u003e\n\u003cli\u003eMarine and vehicle power systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52053960982816,"sku":"PMP482505012","price":598.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-pmp482505012-1.webp?v=1785425041","url":"https:\/\/www.ledandsolar.co.uk\/products\/victron-multiplus-ii-5000va-charger","provider":"LED \u0026 Solar","version":"1.0","type":"link"}