{"product_id":"victron-multiplus-48-1200-13-16-inverter","title":"Victron MultiPlus 48\/1200\/13-16 230V Inverter Charger | PMP482120000","description":"\u003cp\u003eThe Victron MultiPlus 48\/1200\/13-16 combines a 1200VA pure sine wave inverter with a 13A battery charger in one enclosure, built for 48V battery systems delivering 230V AC. It suits off-grid setups, backup power arrangements and mobile or marine installations where a compact inverter charger is needed. A VE.Bus port ties the unit into wider Victron monitoring and control systems.\u003c\/p\u003e\u003ch2\u003ePower inverter charger for 48V systems\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter output\u003c\/strong\u003e, 1200VA continuous, pure sine wave, at 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery charger\u003c\/strong\u003e, 13A multi-stage charging with an adaptive algorithm based on usage history\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC passthrough\u003c\/strong\u003e, 16A, with automatic transfer switching from shore power or generator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerAssist\u003c\/strong\u003e, draws extra power from the battery when load exceeds the available AC input, preventing generator overload\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Bus interface\u003c\/strong\u003e, allows parallel or three-phase configuration with other compatible MultiPlus units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer time\u003c\/strong\u003e, virtually instantaneous switching between mains and inverter, suitable for sensitive electronics\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow it works\u003c\/h2\u003e\u003cp\u003eThe 48V DC input suits systems where a higher-voltage battery bank reduces cable losses over longer runs. The 230V AC output is compatible with standard UK and European loads. When mains or generator supply is limited, PowerAssist takes the shortfall from the battery bank rather than tripping a breaker, and the changeover between supply sources happens with virtually no interruption to connected equipment.\u003c\/p\u003e\u003cp\u003eVE.Bus connectivity supports parallel operation with additional MultiPlus units for higher output, or split-phase and three-phase arrangements. The unit also works with Victron's GX monitoring devices, Venus OS, VictronConnect and VEConfigure for commissioning and remote monitoring.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003ePMP482120000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Output Power\u003c\/td\u003e\n\u003ctd\u003e1200VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Output\u003c\/td\u003e\n\u003ctd\u003e13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Current\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eVE.Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e8719076039334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOff-grid cabins and rural properties running a 48V battery bank with generator backup\u003c\/li\u003e\n\u003cli\u003eMarine and narrowboat installations needing 230V AC from a 48V DC house bank\u003c\/li\u003e\n\u003cli\u003eVehicle-based systems with a 48V electrical architecture\u003c\/li\u003e\n\u003cli\u003eBackup power for critical loads in residential or light commercial premises\u003c\/li\u003e\n\u003cli\u003eScalable off-grid systems where extra MultiPlus units can be added in parallel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Victron MultiPlus 48\/1200\/13-16 230V VE.Bus inverter charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFitting should be carried out by a qualified electrician or accredited installer experienced with battery-based inverter systems. The unit needs an appropriately rated 48V DC battery bank with correctly sized DC cabling and fusing. Any connection to the public grid must meet G98 or G99 requirements as applicable, with notification to the local Distribution Network Operator.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095575589152,"sku":"PMP482120000","price":326.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-pmp482120000-1.webp?v=1785754181","url":"https:\/\/www.ledandsolar.co.uk\/products\/victron-multiplus-48-1200-13-16-inverter","provider":"LED \u0026 Solar","version":"1.0","type":"link"}