{"product_id":"multiplus-48-2000-inverter-charger","title":"Victron MultiPlus 48\/2000\/25-32 Inverter Charger 230V | PMP482200000","description":"\u003cp\u003eThe Victron MultiPlus 48\/2000\/25-32 combines a pure sine wave inverter with a battery charger in a single 48V unit for 230V AC systems. It suits off-grid, backup power and marine or vehicle installations that need reliable AC output alongside charging in one enclosure.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter output\u003c\/strong\u003e - 2000VA continuous from a 48V DC battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery charger\u003c\/strong\u003e - 25A output with an adaptive charge algorithm that adjusts to different battery chemistries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC transfer switch\u003c\/strong\u003e - 32A, switching automatically between shore or generator power and the inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Bus interface\u003c\/strong\u003e - for parallel operation, three-phase configuration and system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerControl\u003c\/strong\u003e - limits AC input current draw to protect generators or shore connections from overload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerAssist\u003c\/strong\u003e - draws on the battery bank to support AC input during peak demand, so a smaller generator or shore supply can be used.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe inverter section produces a 230V AC pure sine wave, suitable for sensitive electronics as well as standard loads. The 25A charger uses Victron's adaptive algorithm to extend battery life over time. The 32A transfer switch connects to mains or generator supply when present and hands over to inverter operation the moment that source drops.\u003c\/p\u003e\u003cp\u003eVE.Bus lets several MultiPlus units run in parallel, or in split-phase or three-phase arrangements, scaling capacity beyond the standalone 2000VA rating. It also connects to Victron GX devices such as the Cerbo GX, giving remote monitoring and control through the VRM portal.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter output power\u003c\/td\u003e\n\u003ctd\u003e2000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger output\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC transfer switch\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interface\u003c\/td\u003e\n\u003ctd\u003eVE.Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOff-grid solar systems with 48V battery banks needing AC output and integrated charging.\u003c\/li\u003e\n\u003cli\u003eBackup power installations requiring automatic switchover from mains to inverter.\u003c\/li\u003e\n\u003cli\u003eMarine and motorhome systems needing shore power integration with battery charging.\u003c\/li\u003e\n\u003cli\u003eGenerator-backed systems where PowerControl prevents generator overload.\u003c\/li\u003e\n\u003cli\u003eMulti-unit installations using VE.Bus parallel or three-phase configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation should be carried out by a qualified electrician familiar with battery-based inverter systems. Connections to the 48V battery bank, AC distribution board and any generator or mains supply must meet current UK wiring regulations (BS 7671). Grid-connected or export applications may need G98 or G99 compliance and notification to the local network operator.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095598854432,"sku":"PMP482200000","price":405.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-pmp482200000-1.webp?v=1785754550","url":"https:\/\/www.ledandsolar.co.uk\/products\/multiplus-48-2000-inverter-charger","provider":"LED \u0026 Solar","version":"1.0","type":"link"}