{"title":"Victron High Power Chargers","description":"\u003cp\u003eVictron's high power chargers are built for large battery banks where fast, accurate charging matters. The Skylla-TG, Skylla-i, and Centaur ranges deliver high output currents with adaptive multi-stage charging algorithms that protect battery life while charging as quickly as the bank will allow.\u003c\/p\u003e\u003cp\u003eThese are the chargers for industrial, commercial, and large off-grid installations running 24V and 48V battery systems, not small leisure setups. Each unit integrates with the Victron GX monitoring platform, so you get full remote visibility and control over charging status.\u003c\/p\u003e\u003cp\u003eChoice between ranges comes down to output current and input voltage. Centaur units run on 120-240V, while Skylla-TG and Skylla-i models offer both 230V and 120-240V options across a range of output currents to match the battery bank size.\u003c\/p\u003e","products":[{"product_id":"victron-skylla-i-24-80-marine-charger","title":"Victron Skylla-i 24\/80 (1+1) 230V Battery Charger | SKI024080000","description":"\u003cp\u003eThe Victron Skylla-i 24\/80 (1+1) is a three-stage battery charger for 24V systems, delivering up to 80A of charge current. The (1+1) configuration adds a dedicated 4A output for a second battery bank, so a service battery and a starter or auxiliary battery can be charged from one unit. It suits marine, vehicle, industrial and off-grid installations.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charger use\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary output\u003c\/strong\u003e, 80A for 24V battery banks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary output (1+1)\u003c\/strong\u003e, 4A for a second battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, three-stage adaptive (bulk, absorption, float) with an optional storage mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, flooded lead-acid, AGM, gel and lithium-ion (with appropriate BMS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel operation\u003c\/strong\u003e, multiple Skylla-i units can be synchronised for larger battery banks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity\u003c\/strong\u003e, VE.Bus, for integration with Victron Quattro inverter\/chargers and GX monitoring devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 230V, suitable for shore power, generator or mains supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eOn yachts, narrowboats and commercial vessels it charges service and starter battery banks from shore power or a generator. In commercial vehicles and motorhomes it maintains a large leisure battery bank alongside the vehicle starter battery. Off-grid cabins and industrial sites use it for bulk charging 24V banks, and it can also keep standby or UPS battery banks topped up. Within a Victron VE.Bus system, it runs as a managed charger alongside Quattro inverter\/chargers, with charge current adjusted according to available AC input.\u003c\/p\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eFitting should be carried out by a qualified electrician or marine electrical engineer. Both the 230V AC connection and the 24V DC battery connection need correctly rated fusing and cable cross-section. Marine installations should follow relevant ISO or ABYC wiring standards, and lithium battery banks require a compatible BMS with charge enable\/disable functionality.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Victron Skylla-i 24\/80 (1+1) 230V battery charger\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52061068099872,"sku":"SKI024080000","price":831.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-ski024080000-1.webp?v=1785511058"},{"product_id":"centaur-24-60-battery-charger","title":"Victron Centaur Charger 24\/60(3) 120-240V Charger | CCH024060000","description":"\u003cp\u003eThe Victron Centaur 24\/60(3) is a mains-powered battery charger with three independent output channels, built for charging separate battery banks from a single unit. It runs from a wide AC input of 120 to 240V, so it works across UK, European and other mains supplies without adjustment.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 60A total at 24V, split across three separate charging terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, accepts 120 to 240V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging profile\u003c\/strong\u003e, four-stage adaptive algorithm covering bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, built-in sensor adjusts output voltage to battery temperature, with an optional external sensor for remote battery locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, suits flooded, gel and AGM lead-acid battery types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery safe mode\u003c\/strong\u003e, protects against deep discharge when the charger is connected to a battery under load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 9.5 kg, in a metal enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Centaur range is transformer-based rather than high-frequency switching, giving it tolerance for poor or unstable mains supplies. That makes it a fit for marine, vehicle, generator and industrial settings where mains quality varies. The 60A output at 24V is divided across three terminals, so a starter battery, a domestic bank and a third bank can all be charged from one charger.\u003c\/p\u003e\u003cp\u003eThe adaptive charging profile responds to what the battery needs rather than running a fixed timer. During absorption the charger tracks current draw and only moves to float once the battery is actually full. Storage mode then lowers voltage further, reducing electrolyte loss and mains draw for batteries left connected for long periods.\u003c\/p\u003e\u003ch3\u003eTemperature sensing\u003c\/h3\u003e\u003cp\u003eA built-in sensor handles temperature compensation, and an external sensor is available where the charger and battery sit in different locations, such as a separate engine room or battery compartment.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with separate engine start, bow thruster and domestic banks.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles, coaches and motorhomes charging multiple banks from shore power.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and buildings using a generator for AC charging.\u003c\/li\u003e\n\u003cli\u003eIndustrial and telecoms backup power with multiple lead-acid strings.\u003c\/li\u003e\n\u003cli\u003eRental fleets and plant equipment needing overnight charging from one mains connection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eVictron Centaur Charger 24\/60 (3 outputs) unit\u003c\/li\u003e\n\u003cli\u003eMains AC connection, hardwired, no plug supplied\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eThis is a hardwired unit and should be installed by a qualified electrician. The AC input needs an appropriately rated circuit breaker and wiring compliant with local regulations, which in the UK means BS 7671. Allow ventilation around the unit, as the transformer generates heat under sustained charging, and fuse battery connections close to the terminals with correctly rated cable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095393136928,"sku":"CCH024060000","price":674.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch024060000-1.webp?v=1785748184"},{"product_id":"skylla-tg-24-30-marine-charger","title":"Victron Skylla-TG 24\/30 (1+1) Battery Charger 120-240V | SDTG2400301","description":"\u003cp\u003eThe Victron Skylla-TG 24\/30 (1+1) is a transformer-based battery charger for 24V systems, built to deliver 30A to a main battery bank while keeping a starter battery topped up through its dedicated (1+1) output. A wide AC input range of 120 to 240V lets it run from mains supplies or generator power without manual voltage selection, which suits marine, vehicle and off-grid installations that switch between AC sources.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charger use\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain output\u003c\/strong\u003e, 30A for 24V battery systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual output\u003c\/strong\u003e, (1+1) configuration charges a starter battery alongside the main bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input range\u003c\/strong\u003e, 120 to 240V AC, no manual adjustment needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger type\u003c\/strong\u003e, transformer-based design with galvanic isolation between AC and DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge control\u003c\/strong\u003e, Victron's adaptive algorithm adjusts the charge profile to battery condition\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG range uses a transformer topology rather than switched-mode circuitry, giving true galvanic isolation. That matters where DC and AC grounds need to stay separate, and it also makes the charger tolerant of rough AC input such as generator power with voltage fluctuations or harmonic distortion.\u003c\/p\u003e\u003cp\u003eThe (1+1) output arrangement means two DC outputs are managed at once: the primary delivers 30A to the main bank, while the secondary maintains a starter or auxiliary battery independently, so neither is left unmanaged while the charger runs.\u003c\/p\u003e\u003ch3\u003eAC input flexibility\u003c\/h3\u003e\u003cp\u003eBecause the input accepts 120 to 240V, the same unit works on North American 120V supplies, European 230V mains, or typical generator output without rewiring or switch changes.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed on marine vessels needing isolated charging for main and starter banks, in coaches and motorhomes with 24V house systems and a separate starter battery, and in off-grid or industrial sites running on generator power with variable AC output. It also suits telecom and industrial backup systems needing 24V float and absorption charging.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/30 (1+1) 120-240V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this charger with a qualified electrician or marine electrical engineer. Connect it to a correctly rated AC supply with suitable overcurrent protection, size the DC connections for the full output current, and check that the galvanic isolation meets the relevant classification society or national standard for marine use. Allow adequate ventilation around the unit while it operates.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095393169696,"sku":"SDTG2400301","price":480.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400301-1.webp?v=1785748190"},{"product_id":"skylla-i-24-100-marine-charger","title":"Victron Skylla-i 24\/100 (1+1) 230V Marine Battery Charger | SKI024100000","description":"\u003cp\u003eThe Victron Skylla-i 24\/100 (1+1) is a 24V battery charger that delivers 100A of charge current from a 230V AC supply. It suits professional and commercial installations where high-current, reliable charging matters, and its (1+1) configuration gives two independently controlled output banks for systems with separate battery banks or split charge distribution.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge output\u003c\/strong\u003e, 100A total at 24V from a single 230V AC input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual bank configuration\u003c\/strong\u003e, (1+1) output lets two battery banks charge independently from one unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptive charging\u003c\/strong\u003e, four-stage algorithm covering bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input protection\u003c\/strong\u003e, charge current is reduced automatically if AC input power is limited, avoiding generator or shore power overload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem integration\u003c\/strong\u003e, VE.Bus and VE.Net compatible for use with Victron monitoring and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, built-in input for a battery temperature sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eA high-frequency switching topology gives the Skylla-i a stable, regulated output. The four-stage adaptive algorithm moves through bulk, absorption, float and storage based on the battery's actual state rather than a fixed timer, which helps batteries held on standby or backup duty avoid the wear that comes from prolonged overcharging.\u003c\/p\u003e\u003cp\u003eThe (1+1) split provides one primary 100A output bank and one auxiliary bank. That's useful in marine, vehicle or off-grid setups with a starter battery and a separate service bank: the auxiliary output charges the secondary bank once the primary reaches float, so the main bank isn't drawn down and a second charger isn't needed.\u003c\/p\u003e\u003cp\u003eVE.Bus and VE.Net connectivity lets the Skylla-i sit inside a larger Victron system. Charge parameters can be adjusted remotely, and the unit responds to system-level commands such as current limiting, which matters when it's fed from a generator with a fixed kVA rating. Charge parameters are also programmable via Victron software to suit different battery chemistries.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels needing high-current charging of service and starter banks from shore power or a generator.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and remote sites running a generator as the main AC source.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles, coaches and motorhomes with large 24V battery banks.\u003c\/li\u003e\n\u003cli\u003eBackup power and UPS systems needing fast recharge between discharge cycles.\u003c\/li\u003e\n\u003cli\u003eIndustrial and telecoms standby battery systems needing programmable charge profiles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-i 24\/100 (1+1) 230V battery charger unit.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation should be carried out by a qualified electrician. The unit takes a 230V AC supply and outputs high DC currents, so cable sizing, fusing and ventilation need to be correct, and battery connections must be rated for the full 100A output. Configuration within a VE.Bus or VE.Net system should be done using Victron software by an installer familiar with the platform, in a dry location with clearance for airflow.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095393464608,"sku":"SKI024100000","price":1005.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-ski024100000-1.webp?v=1785748251"},{"product_id":"centaur-marine-battery-charger-60a","title":"Victron Centaur 12\/60(3) 3-Output Battery Charger 120-240V | CCH012060000","description":"\u003cp\u003eThe Victron Centaur 12\/60(3) is a mains-powered battery charger with three independent outputs, delivering up to 60A total to 12V battery banks. It runs from a 120-240V AC supply, so it works on UK and EU shore power as well as North American mains without modification.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 60A total, spread across three independent outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V, covering both European and North American supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive four-stage process: bulk, absorption, float and storage, with automatic temperature compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, gel, AGM, tubular plate and flooded lead-acid, with selectable charge profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery safe mode\u003c\/strong\u003e, protects against damage when charging deeply discharged batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 6.7kg, housed in a metal enclosure for permanent installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow it charges\u003c\/h2\u003e\u003cp\u003eBulk stage delivers maximum current to bring the battery up to voltage quickly. Absorption holds voltage steady while current tapers off. Float then maintains full charge without overcharging, and storage mode reduces float voltage if the battery stays connected for long periods.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuits vessels with separate starter, domestic and auxiliary battery banks, since each output is managed independently. Deep discharge on one bank does not affect charge quality on the others. Also used in motorhomes, off-grid cabins, industrial vehicles and standby power installations with multiple 12V battery systems.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eVictron Centaur Charger 12\/60(3) 120-240V unit\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003cli\u003eDocumentation and quick-start guide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician familiar with mains-connected charging equipment, on a correctly fused and earthed AC supply. Size battery cabling for 60A continuous current and keep runs as short as practicable. Allow ventilation around the unit and follow relevant marina and BS EN ISO wiring standards for shore power connections.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095400083744,"sku":"CCH012060000","price":384.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012060000-1.webp?v=1785749059"},{"product_id":"victron-skylla-tg-marine-battery-charger","title":"Victron Skylla-TG 24\/50(1+1) Marine Battery Charger 230V | SDTG2400501","description":"\u003cp\u003eThe Victron Skylla-TG 24\/50(1+1) is a three-phase compatible marine battery charger built for 24V battery banks, delivering 50A to the primary bank with a second, independently regulated output for a smaller auxiliary battery. It runs from a 230V AC supply and suits commercial vehicles, vessels and industrial sites where two separate battery systems need charging at once.\u003c\/p\u003e\u003ch2\u003eMarine battery charger with dual outputs\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary output\u003c\/strong\u003e, 50A at 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e, (1+1) dual output, each independently regulated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 230V, suited to standard shore power or generator supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, adaptive four-stage cycle (bulk, absorption, float, storage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, available via an optional sensor, adjusting charge voltage to battery temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, adjustable voltage and current settings for flooded, gel and AGM lead-acid, and lithium where configured\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e, metal housing with a compact footprint for its output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking\u003c\/strong\u003e, compatible with Victron VE.Can for monitoring and integration with other Victron equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eStorage and monitoring\u003c\/h2\u003e\u003cp\u003eThe absorption stage adjusts to the battery's actual state rather than running on a fixed timer, so a deeply discharged bank gets a full charge while a partly charged one is not overcharged. Storage mode lowers the float voltage once the charger detects the battery has been idle for a while, which helps in long-term standby setups. Connected via VE.Can to a GX device, the charger can be monitored and configured remotely through the Victron Connect app, useful when it is fitted somewhere awkward to reach, such as a machinery bay or below deck.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with separate 24V main and auxiliary battery banks needing simultaneous charging from shore power\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles and coaches with a 24V chassis battery and a separate habitation battery\u003c\/li\u003e\n\u003cli\u003eIndustrial and off-grid 24V battery installations charged from a generator or mains supply\u003c\/li\u003e\n\u003cli\u003eTelecoms and backup power systems that rely on long-term float and storage charging with remote monitoring\u003c\/li\u003e\n\u003cli\u003eMotorhomes and large leisure vehicles running dual 24V battery systems with shore power\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/50(1+1) 230V battery charger\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this charger with a qualified electrician or marine electrical engineer. The AC supply needs correct fusing, and cable sizing on both the AC input and DC output must match the current ratings. Wire the (1+1) outputs to separate, isolated battery banks, and follow the relevant NMEA or flag-state wiring standards for marine work. If linking to a Victron GX device via VE.Can, fit termination resistors at each end of the CAN bus.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095400247584,"sku":"SDTG2400501","price":529.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400501-1.webp?v=1785749082"},{"product_id":"skylla-tg-24-100-marine-battery-charger","title":"Victron Skylla-TG 24\/100(1+1) 230V Marine Battery Charger | SDTG2401001","description":"\u003cp\u003eThe Victron Skylla-TG 24\/100(1+1) is a high power battery charger for 24V systems, delivering up to 100A of charge current from a 230V AC single-phase supply. It is built for marine, off-grid and industrial standby installations where dependable, high-current charging matters.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 24V at up to 100A charge current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e, 1+1 dual output, with a main charge output plus an auxiliary output for a second battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 230V AC single-phase, suited to standard UK and European mains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging\u003c\/strong\u003e, adaptive charge algorithm that adjusts to battery condition over successive cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature sensing\u003c\/strong\u003e, accepts a battery temperature sensor input for temperature-compensated charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e, compatible with Victron VE.Bus and monitoring systems for remote visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettings\u003c\/strong\u003e, adjustable charge voltage and current to suit different battery chemistries and bank sizes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the dual output works\u003c\/h2\u003e\u003cp\u003eThe two outputs are independently regulated. The main output runs the bulk, absorption and float stages for the primary bank, while the auxiliary output keeps a secondary bank topped up at float voltage. This removes the need for a separate trickle charger on the second bank.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG 24\/100(1+1) suits commercial and leisure vessels with two battery banks, large 24V off-grid systems charged from shore power or a generator, industrial standby and UPS battery backup, coaches and heavy vehicles with 24V systems, and telecoms or remote infrastructure sites needing continuous charging.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1x Victron Skylla-TG 24\/100(1+1) 230V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this charger with a qualified electrician or marine electrical engineer experienced with high-current DC systems. The AC supply needs correctly rated overcurrent protection, and DC output cabling must be sized for 100A continuous current and kept as short as practical to limit voltage drop. Marine installs should follow the relevant ISO and NMEA wiring standards, and the unit needs adequate ventilation in operation. If pairing with VE.Bus or a GX device, follow Victron's system design guidance for setup.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095400870176,"sku":"SDTG2401001","price":1008.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2401001-1.webp?v=1785749168"},{"product_id":"centaur-battery-charger-24v-16a","title":"Victron Centaur Charger 24\/16(3) 120-240V | CCH024016000","description":"\u003cp\u003eThe Victron Centaur Charger 24\/16 is a three-output, mains-powered battery charger for marine, vehicle and off-grid systems. It supplies 16A of charge current at 24V to three independently managed battery banks, and accepts AC input from 120 to 240V for use across different mains supplies.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 16A at 24V across three separate output channels for simultaneous multi-bank charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput range\u003c\/strong\u003e, 120 to 240V AC, suitable for UK, European and North American supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, four-stage adaptive cycle (bulk, absorption, float, storage).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, gel, AGM, flooded lead-acid and calcium types via selectable charge profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, output voltage adjusts automatically to ambient conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 4.3 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery safe mode\u003c\/strong\u003e, protects against deep discharge when connected to a battery under load.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the charge cycle works\u003c\/h2\u003e\u003cp\u003eDuring bulk, the charger delivers full current until the battery reaches absorption voltage. Absorption then holds voltage steady while current tapers off, so the battery reaches full charge without overcharging. Float and storage modes hold a safe resting voltage for batteries left connected over long periods, which matters on vessels and vehicles that sit idle between uses.\u003c\/p\u003e\u003ch2\u003eThree independent outputs\u003c\/h2\u003e\u003cp\u003eEach of the three outputs is managed according to its own state of charge, so a starter battery and one or two auxiliary banks can be charged at the same time without separate chargers or manual switching. The 120 to 240V input tolerance means the same unit works from a UK shore power point, a European marina or a North American supply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to marine vessels with separate starter, bow thruster and domestic banks; motorhomes and coaches with chassis and habitation batteries; off-grid cabins and site offices on shore power or generator supply; and commercial vehicles with auxiliary systems for refrigeration or tail-lift equipment.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or marine electrical engineer, wired to a 120 to 240V AC mains supply in accordance with local regulations (BS 7671 in the UK, or relevant ISO\/NMEA standards for marine work). Allow adequate ventilation and make sure DC output cabling is rated for the charge current. Select the correct battery type via the charge profile before commissioning.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 24\/16 (3 outputs) unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095573098784,"sku":"CCH024016000","price":322.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch024016000-1.webp?v=1785753855"},{"product_id":"skylla-tg-24-50-marine-charger","title":"Victron Skylla-TG 24\/50 (1+1) 3-Phase 400V Charger | STG024050300","description":"\u003cp\u003eThe Victron Skylla-TG 24\/50 (1+1) is a three-phase industrial battery charger for 24V systems, delivering up to 50A of charge current from a 3-phase 400V AC supply. It includes a second output stage in a 1+1 configuration, giving redundancy or the ability to charge two battery banks at once.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 50A output for 24V battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 3-phase 400V supply, balancing load across all three phases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1+1 configuration\u003c\/strong\u003e, a second independent output stage for redundant operation or dual-bank charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptive charge algorithm\u003c\/strong\u003e, adjusts absorption time to battery condition, helping prevent overcharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous-duty design\u003c\/strong\u003e, built for marine, industrial and off-grid environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 13.5 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMarine battery charger applications\u003c\/h2\u003e\u003cp\u003eThis charger suits vessels with three-phase shore power and large 24V service or start battery banks, where a marine battery charger needs to run continuously without shutting down under load. It also fits plant rooms, generator rooms and industrial sites with high-capacity lead-acid or GEL banks, and installations where two separate battery banks need independent, simultaneous charging.\u003c\/p\u003e\u003ch3\u003eRedundancy and dual-bank use\u003c\/h3\u003e\u003cp\u003eThe 1+1 architecture means one enclosure holds two output stages. If a critical system, such as backup power or marine propulsion support, needs resilience, one stage can keep charging even if the other develops a fault. That avoids running two separate charger units side by side.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eConnection to a 3-phase 400V AC supply calls for a qualified electrician. DC cabling, fusing and battery bank sizing all need to match the 50A output and 1+1 configuration. For marine installations, check classification society or flag state requirements before fitting, and confirm the battery chemistry and voltage match the charger's output profile before commissioning.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Victron Skylla-TG 24\/50 (1+1) 3-Phase 400V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095573524768,"sku":"STG024050300","price":950.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-stg024050300-1.webp?v=1785753906"},{"product_id":"skylla-tg-24-50-marine-charger-sdtg2400503","title":"Victron Skylla-TG 24\/50(1+1) GL Marine Battery Charger 120-240V | SDTG2400503","description":"\u003cp\u003eThe Victron Skylla-TG 24\/50 (1+1) GL is a transformer-based battery charger for 24V systems, delivering up to 50A of charge current. Built for marine, commercial and industrial duty, it accepts AC input from 120 to 240V and provides a (1+1) dual output for managing two separate battery banks from one unit.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charger use\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 50A output into 24V battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual output\u003c\/strong\u003e, (1+1) configuration charges two separate battery banks independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input range\u003c\/strong\u003e, 120 to 240V, suited to shore power and generator supplies worldwide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e, GL certified for marine and industrial use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging profile\u003c\/strong\u003e, adaptive multi-stage algorithm with temperature-compensated output voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e, aluminium enclosure for professional installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG range is Victron's transformer-based charger series for continuous duty applications. The transformer design gives galvanic isolation between the AC input and DC output, which matters on vessels and installations where ground loops or stray current corrosion are a concern.\u003c\/p\u003e\u003cp\u003eThe (1+1) output topology gives a primary output for the main battery bank and a secondary output for a service or starter battery, each managed independently. This can remove the need for a separate battery-to-battery charger or combiner relay. The wide AC input range means the unit runs correctly on both North American and European shore power, and on most generator outputs.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial and leisure marine vessels needing shore power charging with galvanic isolation.\u003c\/li\u003e\n\u003cli\u003eHeavy vehicles, coaches and motorhomes with large 24V banks and separate starter batteries.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and industrial sites running on generator power.\u003c\/li\u003e\n\u003cli\u003eTelecom and backup power installations requiring continuous-duty charging.\u003c\/li\u003e\n\u003cli\u003eMulti-bank systems where each bank needs its own charge profile.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/50 (1+1) GL battery charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation should be done by a qualified electrician familiar with DC battery systems and AC mains wiring. The AC supply must be correctly fused, and DC cabling sized for 50A continuous current with overcurrent protection on each output. Wire the (1+1) outputs to separate battery banks; do not parallel them. Check battery chemistry compatibility before connecting, as charge voltage settings must match the battery type in use.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095573655840,"sku":"SDTG2400503","price":647.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400503-1.webp?v=1785753920"},{"product_id":"victron-centaur-3-output-charger","title":"Victron Centaur Charger 24\/30(3) 120-240V | CCH024030000","description":"\u003cp\u003eThe Victron Centaur 24\/30 is a three-output mains-powered battery charger built for jobs where more than one battery bank needs attention at the same time. It takes AC input anywhere from 120 to 240V, so it works on UK, European or North American supplies without a manual voltage switch. Marine, vehicle, off-grid and industrial installers use it where automatic, unattended charging matters.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 30A total at 24V across three independent output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, accepts 120 to 240V without manual adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive four-stage cycle covering bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, output voltage adjusts to battery temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, works with flooded, gel and AGM lead-acid types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e, sealed against reverse polarity, short circuit and high temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 5kg, suited to permanent fitting in tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the adaptive charging works\u003c\/h2\u003e\u003cp\u003eThe Centaur adjusts absorption time based on the previous charge cycle. A heavily discharged battery gets a longer absorption phase; a lightly used one gets a shorter one, cutting gassing and heat. Fixed-time chargers cannot do this, and battery life suffers as a result.\u003c\/p\u003e\u003cp\u003eEach of the three outputs is managed independently. The charger can push full current into a depleted bank while holding another on float, which suits boats and vehicles running separate starter, service and bow thruster batteries.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine installations charging starter, service and auxiliary banks together.\u003c\/li\u003e\n\u003cli\u003eMotorhomes, coaches and commercial vehicles with 24V systems.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins running from generator or shore power.\u003c\/li\u003e\n\u003cli\u003eIndustrial and telecoms backup systems needing automatic maintenance.\u003c\/li\u003e\n\u003cli\u003eRental fleets and plant equipment kept topped up between uses.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this by a qualified electrician on a correctly fused, earthed AC supply. Check the battery bank matches the 24V output before wiring in. Leave room around the unit for airflow during long charge cycles, and on boats follow the relevant BMEA or IEC wiring standards. Keep it away from direct water ingress.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 24\/30 (3 outputs) unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095573754144,"sku":"CCH024030000","price":440.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch024030000-1.webp?v=1785753936"},{"product_id":"marine-battery-charger-skylla-ip65-12-70","title":"Victron Skylla-IP65 12\/70 (1+1) Marine Battery Charger 120-240V | SKY012070000","description":"\u003cp\u003eThe Victron Skylla-IP65 12\/70 (1+1) is a 12V, 70A battery charger built for marine, vehicle and industrial use. Its IP65-rated enclosure copes with wet or dusty locations that would put a standard charger out of action, making it a practical marine battery charger for boats, coaches and off-grid systems. The (1+1) output configuration gives one main output plus a dedicated starter battery output, so two separate battery banks can be charged at once.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 12V, 70A main output with a second output for starter battery charging via the (1+1) configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 enclosure\u003c\/strong\u003e, protection against dust ingress and low-pressure water jets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, wide 120-240V range, covering European, UK and North American shore power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive 4-stage bulk, absorption, float, storage profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, works with flooded, gel, AGM and lithium-ion batteries with correct settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e, VE.Direct port for use with Victron GX devices and the VictronConnect app.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eBuilt for demanding installations\u003c\/h2\u003e\u003cp\u003eThe Skylla-IP65 range suits environments where moisture, vibration and variable shore power are routine. The IP65 rating lets it be mounted in engine rooms, on deck, in vehicle bays or in outdoor enclosures without a separate weatherproof housing. Because the AC input spans 120-240V, the same unit runs on UK, EU and North American supplies, which helps on vessels or vehicles that cross regions.\u003c\/p\u003e\u003cp\u003eThe (1+1) output topology suits any setup with separate service and starter battery banks. The 70A main output covers the service bank while the second output maintains the starter battery independently, removing the need for a separate battery-to-battery charger. Each output's charge parameters can be set independently, useful where the two banks differ in chemistry or capacity.\u003c\/p\u003e\u003cp\u003eA built-in battery temperature sensor input allows charge voltage compensation across changing ambient conditions. VE.Direct connectivity links the charger into a wider Victron system: connected to a Cerbo GX or similar device, charge status, voltage and current show on the GX display or via the VRM portal. VictronConnect handles configuration of charge algorithms, voltage thresholds and battery type without opening the unit. The housing is aluminium, weighs 6.5 kg and has a compact form factor for panel or bulkhead mounting.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels needing simultaneous charging of service and starter battery banks from shore power.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles, coaches and motorhomes with separate leisure and engine battery systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment and off-grid installations in outdoor or semi-exposed locations.\u003c\/li\u003e\n\u003cli\u003eBackup power systems operating in non-climate-controlled environments.\u003c\/li\u003e\n\u003cli\u003eInstallations requiring compatibility with both 120V and 240V AC supplies across different regions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-IP65 12\/70 (1+1) battery charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation should be carried out by a qualified electrician familiar with DC battery systems and AC mains wiring. The AC supply must be correctly fused and DC output cabling rated for the full 70A output. The IP65 rating relies on all cable entry points being properly sealed with suitable glands to maintain ingress protection. Marine installations should follow the relevant standards for electrical installation on vessels.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095574704416,"sku":"SKY012070000","price":548.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sky012070000-1.webp?v=1785754090"},{"product_id":"skylla-tg-marine-battery-charger","title":"Victron Skylla-TG 48\/25(1) 230V Battery Charger | SDTG4800251","description":"\u003cp\u003eThe Victron Skylla-TG 48\/25(1) is a transformer-based 48V battery charger rated at 25A continuous output, built for off-grid, marine and industrial systems that need dependable high-current charging from a 230V single-phase AC supply.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 48V at 25A continuous, up to 1,200W of charge power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, single-phase 230V with wide input voltage tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, adaptive 4-stage: bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, available via an optional sensor to protect battery life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e, compact, wall-mountable, weighing 5.5 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e, works with Victron VE.Bus and optional system monitoring interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eBuilt for demanding AC conditions\u003c\/h2\u003e\u003cp\u003eUnlike switch-mode chargers, the Skylla-TG's transformer-based design gives galvanic isolation and tolerates poor or unstable mains, which suits generator-fed systems, shore power connections and industrial sites where AC quality varies. Lead-acid chemistries including AGM, gel and flooded batteries are all supported.\u003c\/p\u003e\u003cp\u003eThe adaptive charge algorithm adjusts absorption time based on the previous discharge, cutting unnecessary gassing and helping battery life. Storage mode drops the voltage to a low maintenance level when a battery sits connected without cycling for long periods. The (1) designation refers to the unit's parallel output configuration, allowing two Skylla-TG 48\/25 units to be combined for higher charge current.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOff-grid 48V battery banks needing high-current charging.\u003c\/li\u003e\n\u003cli\u003eMarine vessels with 48V house battery systems on shore power or generator supply.\u003c\/li\u003e\n\u003cli\u003eIndustrial and telecoms backup power installations.\u003c\/li\u003e\n\u003cli\u003eGenerator-fed charging where AC input quality is inconsistent.\u003c\/li\u003e\n\u003cli\u003eParallel charging with a second Skylla-TG 48\/25 unit for increased output.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1x Victron Skylla-TG 48\/25(1) 230V battery charger\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstall with a qualified electrician, in line with current wiring regulations (BS 7671 in the UK) and any applicable marine electrical standards. Allow adequate ventilation around the unit during operation. The temperature sensor and monitoring accessories are sold separately.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095574737184,"sku":"SDTG4800251","price":609.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg4800251-1.webp?v=1785754097"},{"product_id":"skylla-ip65-12-70-3-marine-charger","title":"Victron Skylla-IP65 12\/70(3) Marine Battery Charger 120-240V | SKY012070100","description":"\u003cp\u003eThe Victron Skylla-IP65 12\/70(3) is a three-output, 70A battery charger for 12V battery banks, built for marine, vehicle and industrial use. It carries an IP65 rating and accepts an AC input range of 120 to 240V, so it can run from shore power or generators across the UK, EU and North America.\u003c\/p\u003e\u003ch2\u003eMarine battery charger features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 70A total at 12V, split across three independently configurable outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection\u003c\/strong\u003e, IP65 enclosure, sealed against dust and low-pressure water jets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, accepts 120 to 240V AC, suited to varying shore power standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, four-stage adaptive charging: bulk, absorption, float, storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, configurable profiles for flooded, AGM and gel lead-acid batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, sensor input adjusts charge voltage to battery temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 6.5 kg, metal housing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eIndependent charging across three outputs suits vessels needing separate management of starter, domestic and auxiliary battery banks. The same layout works in motorhomes, coaches and HGVs with multiple 12V banks, and in industrial vehicles or plant working in wet or dusty conditions. The wide AC input range makes it a fit for installations connecting to shore power that varies between 120V and 240V, including off-grid cabins running from a generator.\u003c\/p\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eFit by a qualified electrician or marine electrical engineer. AC connections must meet local wiring regulations, including BS 7671 in the UK, and marine installs should follow relevant ISO or ABYC standards. Allow ventilation around the unit even though the enclosure is sealed, since the charger generates heat in use. Battery cabling needs to be rated for the 70A output and fused at the battery terminals.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-IP65 12\/70(3) battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095575916832,"sku":"SKY012070100","price":598.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sky012070100-1.webp?v=1785754243"},{"product_id":"skylla-tg-marine-battery-charger-stg024100300","title":"Victron Skylla-TG 24\/100(1+1) 3-Phase 400V Battery Charger | STG024100300","description":"\u003cp\u003eThe Victron Skylla-TG 24\/100 (1+1) is a three-phase battery charger built for 24V systems that need up to 100A of charge current. It takes a 3-phase 400V AC input and is suited to industrial, marine and off-grid installations where continuous duty and reliability matter.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charger use\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 100A into a 24V battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e, (1+1) dual module, allowing parallel operation for extra output or redundant operation if one module faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 3-phase 400V, compatible with industrial and commercial supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuild\u003c\/strong\u003e, metal enclosure for fixed installation in plant rooms, vessels and off-grid systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 23.45kg, reflecting a transformer-based internal design rather than switched-mode.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG range uses a transformer-based design instead of switched-mode circuitry. That gives galvanic isolation and tolerance of poor or unstable input power, useful on generator-fed or industrial supplies. The 3-phase 400V input spreads load across phases, cutting peak current draw where single-phase loading is restricted.\u003c\/p\u003e\u003cp\u003eThe (1+1) designation means two independent charger modules share one enclosure. Run in parallel for higher combined output, or in redundant mode so one module keeps charging if the other develops a fault. That matters for telecom backup, marine propulsion support or industrial UPS systems where a charger failure cannot be tolerated.\u003c\/p\u003e\u003cp\u003eAt 100A into a 24V bank, this unit suits large installations such as forklift batteries, sizeable lead-acid standby banks and larger off-grid storage. 24V is common in heavy commercial and marine DC systems that need more current capacity than a 48V equivalent.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLarge lead-acid or gel battery banks in industrial standby and UPS systems.\u003c\/li\u003e\n\u003cli\u003eMarine vessels with 24V DC systems and three-phase shore power.\u003c\/li\u003e\n\u003cli\u003eOff-grid installations with generator-based charging and large battery storage.\u003c\/li\u003e\n\u003cli\u003eTelecom and critical infrastructure backup power needing charger redundancy.\u003c\/li\u003e\n\u003cli\u003eForklift and electric vehicle charging on commercial premises with 3-phase supply.\u003c\/li\u003e\n\u003cli\u003eRenewable energy systems with large 24V banks needing high charge current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/100 (1+1) 3-Phase 400V charger unit.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation must be carried out by a qualified electrician. Connection to a 3-phase 400V supply must comply with current UK and EU wiring regulations, with suitable upstream protection fitted. The unit weighs 23.45kg and needs secure, ventilated mounting in a fixed position. Battery connections should follow the battery manufacturer's specifications and relevant DC wiring standards. Do not install where water ingress is possible unless the enclosure rating has been confirmed as suitable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095577653536,"sku":"STG024100300","price":1452.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-stg024100300-1.webp?v=1785754340"},{"product_id":"victron-skylla-marine-battery-charger-24v","title":"Victron Skylla-IP65 24\/35(3) Marine Battery Charger 120-240V | SKY024035100","description":"\u003cp\u003eThe Victron Skylla-IP65 24\/35(3) is a three-output battery charger built for marine and professional installations where several battery banks need charging from one AC source. It delivers 35A at 24V across three independent output channels, and its IP65 enclosure copes with dust and low-pressure water jets, making it suitable for a marine battery charger role on boats and vehicles alike.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charger use\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 35A at 24V across three separate channels for independent battery bank charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e, IP65 rated against dust ingress and low-pressure water jets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V range, covering UK, European and North American supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive four-stage bulk, absorption, float and storage profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, selectable profiles for flooded, gel and AGM lead-acid types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, adjusts charge voltage according to battery temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e, aluminium enclosure weighing 6.5 kg for fixed installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe three-output design suits vessels with a main bank plus auxiliary banks, such as a bow thruster battery and a domestic supply, each charged to its own profile without cross-interference. Motorhomes and commercial vehicles with 24V systems, off-grid cabins running on generator or shore power, and industrial equipment in dusty or wet conditions all fall within its intended use. The wide AC input tolerance also helps where generator voltage fluctuates.\u003c\/p\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eFitting should be done by a qualified electrician, with AC supply correctly fused and cable sizing on both AC input and DC output matched to the unit's current ratings. The three outputs connect to compatible 24V lead-acid battery banks; lithium batteries should only be connected once the charge profile has been confirmed suitable. Mount on a solid surface with good ventilation, even though the enclosure itself is sealed to IP65.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1x Victron Skylla-IP65 24\/35(3) 120-240V battery charger\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095578046752,"sku":"SKY024035100","price":588.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sky024035100-1.webp?v=1785754385"},{"product_id":"victron-centaur-battery-charger-100a","title":"Victron Centaur Charger 12\/100(3) 3-Output 120-240V | CCH012100000","description":"\u003cp\u003eThe Victron Centaur Charger 12\/100(3) is a three-output 12V battery charger delivering 100A total charge current. It accepts AC input from 120 to 240V, so the same unit can be used on shore power or generator supply across the UK, Europe and North America. It is built for professional installation in marine, vehicle and stationary off-grid systems that need reliable, high-current charging across multiple battery banks.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 100A total at 12V, split across three independent outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V AC, suited to varying grid and generator supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging\u003c\/strong\u003e, three-stage adaptive algorithm covering bulk, absorption and float\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery types\u003c\/strong\u003e, compatible with flooded, gel and AGM lead-acid batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl\u003c\/strong\u003e, microprocessor-controlled with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 12kg, transformer-based construction\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the three outputs work\u003c\/h2\u003e\u003cp\u003eEach of the three outputs is independently regulated, which matters on boats and vehicles with separate battery banks for engine starting, domestic loads and bow thrusters. A discharged domestic bank does not pull current away from the starter battery, because each output charges its bank on its own terms.\u003c\/p\u003e\u003ch3\u003eCharging stages\u003c\/h3\u003e\u003cp\u003eBulk charge applies the full 100A to bring batteries up quickly. Absorption holds voltage steady while current tapers off. Float then maintains full charge without overcharging, which helps battery service life compared with a simple constant-voltage charger. A built-in temperature sensor reduces charge voltage as battery temperature rises, useful in engine rooms and enclosed compartments.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits marine vessels running separate engine start, domestic and thruster banks, large motorhomes and coaches on shore power, off-grid cabins running from a generator, and commercial or hire fleet installations needing dependable recharging between uses.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 12\/100(3) 120-240V unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eInstallation should be carried out by a qualified electrician or marine electrical engineer, with the unit connected to a correctly fused and earthed AC supply. Allow ventilation around the charger, especially in enclosed spaces. DC cables should be sized for 100A continuous current and kept short to limit voltage drop. Check battery chemistry before connecting, since charge profiles differ between flooded, gel and AGM types.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095599313184,"sku":"CCH012100000","price":783.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012100000-1.webp?v=1785754638"},{"product_id":"victron-skylla-tg-marine-charger-24-100","title":"Victron Skylla-TG 24\/100 (1+1) GL Marine Battery Charger | SDTG2401003","description":"\u003cp\u003eThe Victron Skylla-TG 24\/100 (1+1) GL is a 24V battery charger rated at 100A output, built for continuous-duty marine, vehicle and industrial installations. The (1+1) configuration adds a dedicated output for a starter battery alongside the main bank, so one unit maintains both without a second charger. AC input runs from 120 to 240V, covering different supply voltages across regions.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 100A at 24V nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual output\u003c\/strong\u003e, (1+1) configuration with a main bank output and a separate output for a starter or auxiliary battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input range\u003c\/strong\u003e, 120 to 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e, GL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e, aluminium, for fixed installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, adaptive four-stage (bulk, absorption, float, storage)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe 24\/100 model sits at the top of Victron's fixed high-current charger range, delivering up to 100A into a 24V bank. That is enough for large lead-acid banks on commercial vessels, heavy vehicles, off-grid systems and industrial UPS installations. The (1+1) output keeps a starter or auxiliary battery topped up independently of the main bank.\u003c\/p\u003e\u003cp\u003eThe wide 120 to 240V AC input suits installations where supply voltage varies, or where the same unit needs to work in different countries. GL certification confirms the unit has been assessed against internationally recognised safety standards. At 9.85kg it is intended for permanent panel or bulkhead mounting rather than portable use.\u003c\/p\u003e\u003cp\u003eThe adaptive algorithm adjusts absorption time based on how long bulk charging took, reducing stress on a battery that started partially charged. Storage mode lowers the float voltage after extended charging, cutting electrolyte loss and plate corrosion over time.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCommercial and leisure vessels needing simultaneous charging of main and starter banks. Off-grid and backup systems with large 24V lead-acid banks. Heavy vehicles, coaches and motorhomes with high-capacity house batteries. Industrial UPS and standby systems. Generator-fed setups where AC supply voltage varies between 120V and 240V.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/100 (1+1) GL charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this charger with a qualified electrician or accredited marine\/electrical engineer. It operates at mains voltage and connects to large battery banks, both hazardous if wired incorrectly. Ensure the AC supply is correctly fused and DC cabling is rated for the full 100A output. Battery connections need appropriately sized cable and correctly rated DC protection. Marine installations should follow the relevant flag state and classification society requirements. Consult the Victron Skylla-TG installation manual for wiring diagrams, ventilation requirements and configuration before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095600591136,"sku":"SDTG2401003","price":1151.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2401003-1.webp?v=1785754723"},{"product_id":"victron-skylla-tg-battery-charger-48v","title":"Victron Skylla-TG 48\/50(1) Battery Charger 230V | SDTG4800501","description":"\u003cp\u003eThe Victron Skylla-TG 48\/50 is a transformer-based 48V battery charger delivering 50A output, built for continuous-duty charging in marine, off-grid and industrial installations. It runs from a 230V single-phase AC supply and is a strong choice as a marine battery charger for large 48V house battery banks needing galvanic isolation.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 48V nominal battery voltage at 50A output current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 230V single-phase supply for mains or generator connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging profile\u003c\/strong\u003e, four-stage adaptive algorithm covering bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, adjusts output voltage based on battery temperature to protect cell life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable settings\u003c\/strong\u003e, charge voltage and current can be set to suit different battery chemistries and bank sizes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuild\u003c\/strong\u003e, metal enclosure rated for industrial environments, weighing 10 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote control\u003c\/strong\u003e, on\/off and charge current can be adjusted via an external signal input.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG range uses a transformer-based design rather than switch-mode circuitry, giving galvanic isolation between the AC input and DC output. This is a requirement in many marine and industrial installations. The 48\/50 variant is suited to large lead-acid or gel battery banks where controlled, high-current recharging matters.\u003c\/p\u003e\u003cp\u003eThe four-stage cycle runs automatically. Bulk delivers maximum current. Absorption holds voltage steady while current tapers off. Float keeps the battery topped up without overcharging, and storage mode drops the float voltage for batteries left idle for long periods. A connected temperature sensor lets the charger adjust absorption and float voltages, which helps where ambient temperatures swing widely.\u003c\/p\u003e\u003cp\u003eRemote inputs let the charger sit inside a larger control scheme, including generator start\/stop logic, and current can be reduced remotely to manage generator or shore power loading.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLarge off-grid battery banks needing high-current recharge from generator or mains.\u003c\/li\u003e\n\u003cli\u003eMarine vessels with 48V house systems where galvanic isolation is required.\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial backup power with lead-acid or gel battery banks.\u003c\/li\u003e\n\u003cli\u003eTelecom and data centre 48V standby systems.\u003c\/li\u003e\n\u003cli\u003eMotorhomes, coaches and specialist vehicles with high-capacity 48V auxiliary batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 48\/50 battery charger unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or accredited installer. Connect to a 230V single-phase AC supply protected by an appropriately rated breaker, with DC output wiring correctly fused and sized for 50A continuous current. Allow adequate ventilation. For marine use, check that the galvanic isolation meets the relevant classification society or standard, and fit a battery temperature sensor where ambient temperature varies significantly.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095601967392,"sku":"SDTG4800501","price":1128.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg4800501-1.webp?v=1785754945"},{"product_id":"gmdss-marine-battery-charger-24v-30a","title":"Victron Skylla-TG 24\/30 GMDSS Marine Battery Charger | SDTG2400302","description":"\u003cp\u003eThe Victron Skylla-TG 24\/30 GMDSS is a 24V, 30A battery charger built for marine and safety-critical installations that must meet GMDSS (Global Maritime Distress and Safety System) requirements. It takes a wide AC input of 120 to 240V, so it works from shore power or generator supplies on either side of the Atlantic without extra transformers.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 24V at 30A continuous charge current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120 to 240V, suits varying shore power and generator supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e, GMDSS, meeting requirements for distress and safety system battery charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 7.4kg, using a high-frequency transformer design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery type\u003c\/strong\u003e, suitable for lead-acid battery banks used on marine and commercial vessels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuild\u003c\/strong\u003e, part of the wider Skylla-TG range used in professional off-grid, marine and vehicle installations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThis charger is intended for GMDSS battery charging on commercial and passenger vessels, and for maintaining batteries powering emergency communication and safety equipment on ocean-going and coastal vessels. It suits professional marine electrical installations needing a dedicated charger for 24V battery banks, including workboats, ferries and offshore support vessels. The wide AC input range means it can be fitted on vessels that move between North American and European shore power standards without changes to the electrical infrastructure.\u003c\/p\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eFitting GMDSS-compliant charging equipment on commercial vessels is work for a qualified marine electrician, and is subject to flag state and class society survey requirements. The AC supply needs correct rating and circuit breaker protection before connection. Battery cabling should be sized for the 30A output and kept as short as practicable to limit voltage drop. Check battery chemistry compatibility before commissioning. This unit is not intended for DIY installation in safety-critical maritime applications.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/30 GMDSS 120-240V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095604326688,"sku":"SDTG2400302","price":780.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400302-1.webp?v=1785755241"},{"product_id":"victron-skylla-tg-marine-charger-24-50","title":"Victron Skylla-TG 24\/50 GMDSS Marine Battery Charger 120-240V | SDTG2400504","description":"\u003cp\u003eThe Victron Skylla-TG 24\/50 GMDSS is a 24V 50A battery charger built for marine and professional use where GMDSS compliance is required. It runs from a wide AC input range of 120 to 240V, so it works from shore power or generator supplies across different regions without reconfiguration.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 50A charge current at 24V nominal battery voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120 to 240V AC, no manual adjustment needed between supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e, meets GMDSS requirements for regulated maritime vessels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 7.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging\u003c\/strong\u003e, multi-stage algorithm for bulk, absorption and float charging\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMarine battery charger applications\u003c\/h2\u003e\u003cp\u003eThis unit suits GMDSS battery charging on commercial and regulated vessels, and shore power charging where vessels move between 120V and 240V port supplies. It also fits emergency backup battery systems in marine and offshore settings, plus off-grid or industrial 24V battery banks that need a high-current charger with a wide AC input.\u003c\/p\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eFitting must be carried out by a qualified marine electrician or electrical engineer. GMDSS installations on regulated vessels are subject to maritime authority inspection, and incorrect wiring or fusing can affect vessel certification. Confirm battery chemistry compatibility and correctly rated cabling before commissioning.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/50 GMDSS 120-240V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095604982048,"sku":"SDTG2400504","price":942.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400504-1.webp?v=1785755290"},{"product_id":"victron-centaur-marine-battery-charger","title":"Victron Centaur Charger 12\/80(3) 120-240V | CCH012080000","description":"\u003cp\u003eThe Victron Centaur Charger 12\/80(3) is a three-output 80A battery charger for 12V battery banks, accepting AC input from 120 to 240V. It suits marine, vehicle and off-grid installations where multiple battery banks need reliable charging from one unit.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current\u003c\/strong\u003e, 80A total, split across three independent outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input range\u003c\/strong\u003e, 120 to 240V, no manual voltage switching needed for UK or international shore power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree outputs\u003c\/strong\u003e, charge a starter battery, domestic bank and generator start battery independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, microprocessor-controlled adaptive four-stage profile covering bulk, absorption, float and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, suits flooded, gel and AGM lead-acid chemistries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, output voltage adjusts with ambient conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 10.2kg, housed in an aluminium enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Centaur sits in Victron's professional charger range, built for installations running more than one battery bank from a single charger. Each output is managed on its own, so a starter battery and a domestic bank at different states of charge are both handled correctly rather than one dragging down the other.\u003c\/p\u003e\u003cp\u003eThe adaptive algorithm watches battery response through the absorption stage and adjusts charge time rather than running a fixed schedule. Storage mode drops the float voltage once a battery has been sitting fully charged for a while, which cuts electrolyte loss over time.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with separate starter, domestic and bow thruster banks.\u003c\/li\u003e\n\u003cli\u003eMotorhomes and coaches charging chassis and habitation batteries together.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and remote sites running 12V lead-acid systems.\u003c\/li\u003e\n\u003cli\u003eGenerator-backed setups charging multiple banks during run time.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles with auxiliary battery banks needing regular high-current charging.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 12\/80(3) 120-240V unit.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or marine electrical engineer. Fuse the AC supply correctly and size DC output cables for the current on each output. Marine installations should follow applicable BMEA or RCD wiring standards, and battery chemistry settings should be checked before first use to match the installed batteries. Do not mount in an unventilated enclosure, since the unit generates heat under high-current charging.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095605375264,"sku":"CCH012080000","price":642.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012080000-1.webp?v=1785755346"},{"product_id":"victron-centaur-24-40-battery-charger","title":"Victron Centaur 24\/40(3) Battery Charger 120-240V | CCH024040000","description":"\u003cp\u003eThe Victron Centaur Charger 24\/40 is a three-output, mains-powered battery charger built for installations where more than one battery bank needs automatic charging from a single unit. It delivers 40A on a 24V system and accepts an AC input range of 120 to 240V, so it works on both UK and international mains supplies.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e40A output on 24V with three independent output channels for separate battery banks\u003c\/li\u003e\n\u003cli\u003eAC input voltage range of 120 to 240V, no manual adjustment needed\u003c\/li\u003e\n\u003cli\u003eAdaptive four-stage charging (bulk, absorption, float, storage) that responds to battery condition\u003c\/li\u003e\n\u003cli\u003eTemperature-compensated charging available via an optional sensor input\u003c\/li\u003e\n\u003cli\u003eSuitable for flooded, gel and AGM lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-controlled with automatic restart after an AC supply interruption\u003c\/li\u003e\n\u003cli\u003eMetal enclosure, 12kg, intended for fixed installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Centaur sits above Victron's basic single-output chargers, aimed at setups needing more than one maintained battery bank. The primary output can take the full 40A while the secondary outputs keep auxiliary or starter batteries topped up. That suits vessels, larger vehicles and off-grid sites where separate banks feed different loads.\u003c\/p\u003e\u003cp\u003eThe charging algorithm tracks battery voltage and adjusts current and voltage through the cycle, which avoids overcharging in absorption and keeps batteries healthy on float or storage. Because the input range spans 120 to 240V, the same unit works on North American and European or UK supplies.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with separate engine start, service and bow thruster banks\u003c\/li\u003e\n\u003cli\u003eMotorhomes, coaches and commercial vehicles with 24V systems\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and industrial sites needing automatic maintenance from mains or generator power\u003c\/li\u003e\n\u003cli\u003eTelecoms and security installations requiring continuous float charging\u003c\/li\u003e\n\u003cli\u003eRental fleets and plant machinery with 24V electrics\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 24\/40 (3 outputs) unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eConnect to a correctly fused and earthed AC mains supply, carried out by a qualified electrician. DC connections to battery banks should be rated and fused appropriately, and marine wiring must meet applicable marine electrical standards. Check generator voltage and frequency sit within the charger's input range before energising. Installation should be done by someone familiar with battery charging and DC electrical work.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095606948128,"sku":"CCH024040000","price":567.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch024040000-1.webp?v=1785755414"},{"product_id":"victron-skylla-i-on-off-cable","title":"Victron Skylla-i Remote On-Off Cable | ASS030550410","description":"\u003cp\u003eThe Skylla-i Remote On-Off Cable lets you switch a Victron Skylla-i battery charger on or off from a distance, without adding any extra electronics to the installation. It plugs straight into the dedicated remote control port on the charger, so there is no wiring to work out and no adaptor to source.\u003c\/p\u003e\u003ch2\u003eKey features of the Skylla-i remote cable\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e, enables remote on\/off switching of the Victron Skylla-i battery charger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection\u003c\/strong\u003e, plug-and-play fit to the Skylla-i remote control port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e, genuine Victron accessory, matched to the Skylla-i interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply\u003c\/strong\u003e, single cable assembly, SKU ASS030550410.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy remote switching matters\u003c\/h2\u003e\u003cp\u003eThe Skylla-i is a high power, multi-output charger often fitted somewhere awkward: an engine room, a battery compartment, or a locked cabinet. Reaching the unit every time it needs switching is not practical on a boat, coach or off-grid system. This cable moves that control point to wherever you need it, connecting directly to the charger's remote port with no modification required.\u003c\/p\u003e\u003ch3\u003eMultiple chargers\u003c\/h3\u003e\u003cp\u003eIf your system runs more than one Skylla-i unit, each charger needs its own cable. It is a one-to-one connection, not a shared bus.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with the charger installed below deck or in an engine room.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles and coaches with chargers mounted in inaccessible bays.\u003c\/li\u003e\n\u003cli\u003eIndustrial and off-grid systems needing remote switching from a control panel.\u003c\/li\u003e\n\u003cli\u003eCaravans and motorhomes where the charger sits in a locked compartment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eConnect the cable to the remote on\/off port on the Skylla-i. Power down the charger before connecting or disconnecting it. Fitting should be carried out by a qualified electrician or marine electrical engineer familiar with the Skylla-i system, and the cable should not be used with any other charger series.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Skylla-i Remote On-Off Cable (ASS030550410)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095608095008,"sku":"ASS030550410","price":17.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-ass030550410-1.webp?v=1785755555"},{"product_id":"victron-centaur-battery-charger-12-40","title":"Victron Centaur Charger 12\/40(3) 120-240V | CCH012040000","description":"\u003cp\u003eThe Victron Centaur 12\/40(3) is a three-output, mains-powered battery charger built for 12V battery banks with a combined output of up to 40A. It suits marine, vehicle and off-grid installations where separate battery banks need controlled charging from one unit. The 120-240V AC input range covers UK and international mains supplies without manual switching.\u003c\/p\u003e\u003ch2\u003eKey features of the Victron Centaur charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 40A total across three independent outputs, so a main bank and two auxiliary banks can charge at once.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V, suited to UK, European and North American supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, four-stage adaptive process (bulk, absorption, float, storage) that adjusts to battery condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, works with flooded, gel and AGM lead-acid batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, supports an optional sensor input for environments with temperature swings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e, microprocessor control guards against overcharge, short circuit, reverse polarity and high temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuild\u003c\/strong\u003e, wall-mountable enclosure weighing 6.4kg, suited to permanent installation in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the charging stages work\u003c\/h2\u003e\u003cp\u003eBulk charge applies the full 40A output to bring the battery up to voltage quickly. Absorption then holds voltage steady while current tapers, giving a full charge without gassing. Float and storage modes hold safe resting voltages for longer periods, which suits standby and seasonal use.\u003c\/p\u003e\u003ch3\u003eThree outputs, one charger\u003c\/h3\u003e\u003cp\u003eEach output is managed independently, so the unit can prioritise whichever bank needs it most without overcharging the others. On a vessel this covers a starter battery, a domestic bank and a bow thruster or generator start battery from a single charger, removing the need for battery-to-battery chargers or split charge relays in many setups.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with separate starter, domestic and auxiliary battery banks.\u003c\/li\u003e\n\u003cli\u003eMotorhomes and coaches needing simultaneous chassis and habitation battery charging.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and outbuildings with mains or generator power for periodic charging.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles with multiple 12V battery systems.\u003c\/li\u003e\n\u003cli\u003eStandby power installations where batteries must stay at full charge over long periods.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit this charger through a qualified electrician or marine electrical engineer, connected to a correctly fused and earthed AC supply per local wiring regulations (BS 7671 in the UK). Size battery cabling for the 40A output and keep runs short to limit voltage drop. If used, fit the optional temperature sensor directly to the main bank's battery casing. Avoid locations exposed to direct water ingress or with restricted ventilation.\u003c\/p\u003e\u003ch2\u003eWhat's included\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 12\/40(3) 120-240V unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095608783136,"sku":"CCH012040000","price":355.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012040000-1.webp?v=1785755661"},{"product_id":"skylla-i-marine-battery-charger-24-100","title":"Victron Skylla-i 24\/100(3) 230V Marine Battery Charger | SKI024100002","description":"\u003cp\u003eThe Victron Skylla-i 24\/100(3) is a three-output, 24V 100A mains-powered battery charger built for professional and commercial installations. It suits marine, industrial, vehicle and off-grid systems where more than one battery bank needs charging from a single unit.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 100A total at 24V across three independently configurable channels for separate battery banks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, runs from a 230V mains supply, compatible with standard single-phase shore power and generator inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive four-stage charging (bulk, absorption, float, storage) for lead-acid chemistries including AGM, gel and flooded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Bus compatible\u003c\/strong\u003e, integrates with Victron system monitoring and control via a GX device or VE.Bus BMS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, adjusts charge voltage automatically for ambient temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e, aluminium, wall-mountable, suited to engine rooms, battery compartments and plant rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMarine battery charger applications\u003c\/h2\u003e\u003cp\u003eThe three-output design lets one charger service a main house bank, a starter battery and a third auxiliary bank independently, each on its own charge profile. That removes the need for multiple separate chargers where wiring is already complex, on vessels with several 24V banks, commercial vehicles and coaches on shore power, off-grid cabins, industrial standby systems and generator-fed hybrid setups.\u003c\/p\u003e\u003ch3\u003eSystem integration\u003c\/h3\u003e\u003cp\u003ePaired with a GX device such as a Cerbo GX, charge status, output current and battery voltage appear in the Victron Remote Monitoring portal. Remote control, including current limiting, is useful where shore power is restricted or shared with other loads.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eInstallation should be carried out by a qualified electrician or marine electrical engineer. The unit connects to 230V AC and outputs high DC current, so correct cable sizing, fusing and ventilation matter. Marine installers are responsible for compliance with relevant ISO and ABYC standards. Check GX device or BMS firmware compatibility before commissioning. The Skylla-i is not suitable for lithium battery chemistries unless a compatible Victron BMS manages charge cutoff.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-i 24\/100(3) 230V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095609569568,"sku":"SKI024100002","price":1162.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-ski024100002-1.webp?v=1785755783"},{"product_id":"victron-skylla-i-marine-battery-charger","title":"Victron Skylla-i 24\/80(3) 230V Battery Charger | SKI024080002","description":"\u003cp\u003eThe Victron Skylla-i 24\/80(3) is a three-output, 24V 80A mains-powered battery charger built for professional and commercial use. It suits demanding environments needing reliable, high-current charging across multiple battery banks at once, making it a strong marine battery charger for vessels running separate starter, service and auxiliary systems.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 80A total at 24V, split across three independently controlled channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptive charging\u003c\/strong\u003e, automatic battery detection adjusts the charge profile to the connected battery type and condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, single-phase 230V, compatible with shore power, generator supply or mains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Bus port\u003c\/strong\u003e, integrates with Victron GX devices, remote panels and system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, via an optional sensor input, for accurate charge voltage across ambient conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable algorithms\u003c\/strong\u003e, set via VictronConnect or a remote panel for flooded, gel, AGM and lithium chemistries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e, compact, wall-mountable, weighing 8kg.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eEach of the three outputs can be configured independently, useful where a starter battery, a service bank and an auxiliary system all need maintaining from one unit. That avoids running separate chargers and the extra wiring that comes with them.\u003c\/p\u003e\u003cp\u003eVE.Bus connectivity lets the Skylla-i talk to Victron GX devices, Color Control panels and system monitors, giving installers a central view of charge state, voltage and current. In professional marine and vehicle installations, that kind of oversight is often expected rather than optional.\u003c\/p\u003e\u003cp\u003eThe adaptive charging algorithm tracks battery behaviour during each cycle and adjusts the absorption time. A deeply discharged battery gets a longer absorption phase; a well-maintained one finishes sooner. This reduces stress on the battery over time without needing manual adjustment.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels charging starter, service and bow thruster banks simultaneously from shore power.\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles and coaches maintaining multiple 24V systems during layover.\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and plant rooms with a 230V generator supply and several battery banks.\u003c\/li\u003e\n\u003cli\u003eIndustrial UPS and backup systems needing a monitored, high-current 24V charger.\u003c\/li\u003e\n\u003cli\u003eVictron-based systems requiring VE.Bus integration with a GX device or Color Control panel.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-i 24\/80(3) 230V battery charger (1 unit)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eThis unit must be installed by a qualified electrician. It connects to a 230V single-phase AC supply and delivers up to 80A DC, so DC cabling, fusing and battery connections must be correctly rated for each output channel. Configure battery chemistry and charge parameters via VictronConnect or a compatible remote panel before commissioning. Marine installations must comply with applicable marine electrical standards, and a temperature sensor is recommended where thermal variation is significant.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095611240736,"sku":"SKI024080002","price":957.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-ski024080002-1.webp?v=1785755943"},{"product_id":"victron-centaur-marine-battery-charger-cch012030000","title":"Victron Centaur Charger 12\/30(3) 120-240V | CCH012030000","description":"\u003cp\u003eThe Victron Centaur Charger 12\/30(3) is a three-output mains battery charger built for marine, vehicle and off-grid installations. It delivers 30A of charge current to a 12V battery bank and accepts AC input from 120 to 240V, so the same unit works on UK shore power, EU marinas or North American supplies.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 30A at 12V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs\u003c\/strong\u003e, 3 independent channels for separate battery banks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V, suitable for multiple regions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, microprocessor-controlled four-stage bulk, absorption, float and storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, flooded, gel and AGM lead-acid batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e, reverse polarity, short circuit and high temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy three outputs matter\u003c\/h2\u003e\u003cp\u003eEach output is managed independently, so a discharged service or bow thruster battery does not stop the starter battery getting a full charge. This is useful on boats and vehicles running separate banks for different jobs. An optional temperature sensor allows temperature-compensated charging where ambient conditions vary.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMarine vessels with starter, service and bow thruster batteries\u003c\/li\u003e\n\u003cli\u003eMotorhomes and coaches charging chassis and habitation batteries together\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and leisure installations on mains or generator supply\u003c\/li\u003e\n\u003cli\u003eCommercial vehicles and ambulances with auxiliary battery systems\u003c\/li\u003e\n\u003cli\u003eMarina shore power on 120V or 240V circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation\u003c\/h2\u003e\u003cp\u003eFit this charger with a qualified electrician or marine electrical engineer. The AC supply needs correct fusing and earthing, and each DC output should use cable and fusing rated for its battery bank. Follow relevant marine wiring standards where applicable. The unit weighs 4.3kg.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 12\/30(3) 120-240V unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095611568416,"sku":"CCH012030000","price":329.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012030000-1.webp?v=1785755979"},{"product_id":"skylla-tg-24-80-marine-battery-charger","title":"Victron Skylla-TG 24\/80(1+1) 230V Battery Charger | SDTG2400801","description":"\u003cp\u003eThe Victron Skylla-TG 24\/80(1+1) is a three-phase compatible battery charger built for professional and industrial use. It supplies 80A of charge current at 24V, with a (1+1) dual output configuration that charges two separate battery banks at the same time. The unit runs from a 230V AC mains supply and is intended for fixed installation rather than portable use.\u003c\/p\u003e\u003ch2\u003eKey features of this marine battery charger\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 80A at 24V nominal output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual output\u003c\/strong\u003e, (1+1) configuration charges two independent battery banks from one unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 230V AC mains supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, adaptive multi-stage bulk, absorption and float phases based on battery condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, adjusts charge voltage for changing ambient conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Bus compatible\u003c\/strong\u003e, integrates with Victron GX devices and VictronConnect for monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG 24\/80(1+1) suits marine vessels that need to charge house and starter battery banks together, and industrial standby systems running large 24V lead-acid or gel banks. It also fits off-grid installations paired with a generator, telecoms sites needing unattended charging, and commercial vehicles or coaches with two battery banks to manage.\u003c\/p\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eThis is a fixed-installation charger and should be fitted by a qualified electrician. The AC supply needs correct fusing, and DC output cabling should be sized for 80A continuous current with correct polarity and fusing on each output. Marine installations should follow applicable ABYC or ISO wiring standards. Where the charger forms part of a VE.Bus system, set up the configuration in VictronConnect or via a compatible GX device before commissioning.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Skylla-TG 24\/80(1+1) 230V battery charger unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095613600032,"sku":"SDTG2400801","price":869.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400801-1.webp?v=1785756183"},{"product_id":"victron-centaur-12-20-battery-charger","title":"Victron Centaur 12\/20(3) Battery Charger 120-240V | CCH012020000","description":"\u003cp\u003eThe Victron Centaur 12\/20(3) is a three-output mains-powered battery charger built for installations where more than one battery bank needs automatic charging from a single unit. It runs from an AC input between 120 and 240V, so it works on UK, EU and North American supplies without switching.\u003c\/p\u003e\u003ch2\u003eMarine battery charger with three outputs\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A main output plus two 4A auxiliary outputs, so three battery banks can charge at the same time.\u003c\/li\u003e\n\u003cli\u003eAutomatic four-stage charging: bulk, absorption, float and storage, suited to gel, AGM and flooded lead-acid batteries.\u003c\/li\u003e\n\u003cli\u003eAdaptive absorption time based on how long the bulk stage took, rather than a fixed period.\u003c\/li\u003e\n\u003cli\u003eStorage mode drops the float voltage after 24 hours to reduce corrosion and water loss during long idle periods.\u003c\/li\u003e\n\u003cli\u003eTemperature-compensated charging available with an optional sensor.\u003c\/li\u003e\n\u003cli\u003eSealed, vibration-resistant build with protection against reverse polarity, short circuit, overheating and high AC voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTransformer-based design\u003c\/h2\u003e\u003cp\u003eCentaur chargers use a transformer rather than high-frequency switching, which makes them tolerant of voltage spikes and a noisy AC supply. That suits marinas, generator-fed sites and other locations where mains quality varies.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits vessels with separate main and auxiliary battery banks, motorhomes and coaches with leisure and starter batteries on one charger, and standby systems with multiple lead-acid banks. Also works well on narrowboats and static caravans left connected for long periods, thanks to the storage mode.\u003c\/p\u003e\u003ch2\u003eSpecification highlights\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutput voltage: 12V\u003c\/li\u003e\n\u003cli\u003eMain output current: 20A\u003c\/li\u003e\n\u003cli\u003eAuxiliary output current: 4A + 4A\u003c\/li\u003e\n\u003cli\u003eAC input voltage: 120 to 240V AC\u003c\/li\u003e\n\u003cli\u003eWeight: 4.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or competent marine or vehicle electrician, with the AC supply correctly fused and DC cabling rated for the run length and battery configuration. Marine installs should follow applicable NMEA or RCD Directive wiring standards. Not suitable for lithium batteries unless Victron documentation confirms compatibility for that specific battery type.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095614124320,"sku":"CCH012020000","price":296.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012020000-1.webp?v=1785756271"},{"product_id":"marine-battery-charger-24v-35a-skylla","title":"Victron Skylla-IP65 24\/35(1+1) 120-240V Battery Charger | SKY024035000","description":"\u003cp\u003eThe Victron Skylla-IP65 24\/35 is a weatherproof battery charger built for marine, industrial and off-grid installations where a standard indoor unit will not survive the environment. It is IP65 rated, delivers 24V nominal output at 35A continuous charge current, and uses a (1+1) output configuration: one main output for the service bank plus one independent output for a starter or auxiliary battery.\u003c\/p\u003e\u003ch2\u003eMarine battery charger built for exposed installations\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating\u003c\/strong\u003e, IP65, protected against dust and low-pressure water jets from any direction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e, 24V DC at 35A continuous, with (1+1) dual output for a main bank and a separate starter or auxiliary battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120-240V, so the same unit works on UK and European 230V supplies or North American 120V shore power without modification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, adaptive four-stage (bulk, absorption, float, storage) with a temperature sensor input available to adjust charge voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e, VE.Direct port for integration with Victron GX devices and the VictronConnect app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, configurable charge profiles for AGM, gel, flooded lead-acid and lithium chemistries.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe (1+1) topology suits vessels and vehicles that need a service bank charged independently from a starter battery, with the auxiliary output keeping the starter topped up without risk of overcharge. Typical installations include marine vessels on shore power, coaches and motorhomes with 24V systems, off-grid cabins exposed to moisture or dust, industrial plant with 24V battery systems, and backup power in telecoms or security installations where IP-rated hardware is specified.\u003c\/p\u003e\u003ch3\u003eMonitoring and integration\u003c\/h3\u003e\u003cp\u003eThe VE.Direct interface connects to Victron's Cerbo GX and Venus GX for remote charge status and state-of-charge visibility. A compatible GX device or a smartphone running VictronConnect is required separately.\u003c\/p\u003e\u003ch2\u003eWhat's included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eVictron Skylla-IP65 24\/35 (1+1) battery charger unit\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or marine electrical engineer. The AC supply must be correctly fused, with input wiring rated for the charger's maximum input current, and DC output cables sized for 35A continuous current over the relevant cable run. If connecting to a lithium battery, confirm the charge profile matches that chemistry before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095614746912,"sku":"SKY024035000","price":540.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sky024035000-1.webp?v=1785756338"},{"product_id":"victron-skylla-tg-marine-charger-24-30","title":"Victron Skylla-TG 24\/30 (1+1) GL Battery Charger 120-240V | SDTG2400303","description":"\u003cp\u003eThe Victron Skylla-TG 24\/30 (1+1) GL is a transformer-based battery charger built for professional marine and industrial use. It delivers 30A to a 24V main battery bank plus a separate 4A output for a starter or auxiliary battery, and accepts AC input from 120 to 240V so it can be connected to shore power in the UK, Europe or North America without modification.\u003c\/p\u003e\u003ch2\u003eKey features for marine battery charging\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain output\u003c\/strong\u003e, 30A charge current on a 24V battery bank\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary output\u003c\/strong\u003e, 4A for a starter or auxiliary battery, the 1+1 configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input\u003c\/strong\u003e, 120 to 240V AC, wide range shore power compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge algorithm\u003c\/strong\u003e, four-stage adaptive charging: bulk, absorption, float, storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e, GL certified for marine and industrial safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 5.4kg, aluminium enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe Skylla-TG series uses a transformer-based design rather than switch-mode conversion, giving galvanic isolation between the AC input and DC output. This is required under many marine classification society rules and in industrial installations. The 24\/30 variant charges the main bank and starter battery at the same time without mixing charge states between them. The adaptive four-stage algorithm varies absorption time based on the previous discharge, reducing stress on the battery compared with fixed-time charging.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to marine vessels needing GL-certified charging with simultaneous main and starter bank management, off-grid cabins run from a generator with variable voltage, commercial vehicles and motorhomes with 24V house systems and a separate start battery, and industrial equipment that requires galvanic isolation between AC supply and DC battery. It also suits narrowboats, yachts and workboats charging from shore power in European or North American waters.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Victron Skylla-TG 24\/30 (1+1) GL battery charger\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or marine electrical engineer. Fuse the AC supply correctly and size DC cabling for the 30A output. On vessels, follow the relevant classification society guidance and confirm the GL certification meets the vessel's requirements. Check AC supply voltage and frequency fall within the 120 to 240V range before connecting, and do not install where the unit could be exposed to direct water ingress.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095616712992,"sku":"SDTG2400303","price":564.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-sdtg2400303-1.webp?v=1785756511"},{"product_id":"victron-phoenix-battery-charger-24v-16a","title":"Victron Phoenix Charger 24\/16 (2+1) 120-240V | PCH024016001","description":"\u003cp\u003eThe Victron Phoenix Charger 24\/16 (2+1) is a three-output battery charger for 24V battery banks. It supplies up to 16A on its primary output and adds two secondary outputs, so a main service bank and auxiliary batteries can all be kept topped up from one unit. Input voltage runs from 120-240V AC, covering shore power and generator supplies on both sides of the Atlantic.\u003c\/p\u003e\u003ch2\u003eKey features of the Victron Phoenix Charger 24\/16\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput configuration\u003c\/strong\u003e, 24V, 16A on the primary output, with two additional outputs in a 2+1 layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput range\u003c\/strong\u003e, 120-240V AC, no manual switching between regional supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, adaptive four-stage charging (bulk, absorption, float, storage) with automatic battery type detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e, output voltage adjusts to battery temperature to prevent overcharging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 3.6kg, compact enough for confined spaces on boats and vehicles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e, reverse polarity, over-temperature and output short circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring\u003c\/strong\u003e, VE.Direct interface for use with VictronConnect.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow the adaptive charging works\u003c\/h2\u003e\u003cp\u003eThe charger watches battery behaviour during absorption and adjusts charge time to match. A deeply discharged bank gets a full cycle; a lightly discharged one moves to float sooner, cutting unnecessary heat. The 2+1 outputs let the main bank pull full current while the two secondary outputs hold starter or auxiliary batteries at a lower rate.\u003c\/p\u003e\u003ch3\u003eMonitoring and setup\u003c\/h3\u003e\u003cp\u003eVE.Direct connectivity lets you monitor and configure the charger through VictronConnect, either over Bluetooth with a VE.Direct Bluetooth Smart dongle or via USB. Battery type presets and absorption voltage can be set to match the chemistry fitted.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuits marine setups with separate service and starter banks, motorhomes and campervans running a leisure bank alongside an engine start battery, off-grid cabins charged from a generator, and vehicles that need to cope with different regional power standards. It also works well in backup systems maintaining several battery banks at once.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or an experienced marine or vehicle electrician working with DC battery systems. The AC supply must be correctly fused and DC connections rated for the current drawn. Mount in a ventilated spot away from flammable materials, and follow applicable marine wiring standards on vessels. This charger is not grid-tied and does not require G98 or G99 notification.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Phoenix Charger 24\/16 (2+1) 120-240V unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095616745760,"sku":"PCH024016001","price":287.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-pch024016001-1.webp?v=1785756518"},{"product_id":"victron-centaur-battery-charger-12-50","title":"Victron Centaur Charger 12\/50(3) 3-Output 120-240V | CCH012050000","description":"\u003cp\u003eThe Victron Centaur Charger 12\/50(3) is a three-output battery charger for 12V systems, delivering 50A total charge current split across three independent outputs. It accepts AC input from 120 to 240V, so the same unit works on shore supplies in the UK, Europe or North America without manual adjustment.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge current\u003c\/strong\u003e, 50A total, split across three outputs for 12V battery banks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC input range\u003c\/strong\u003e, 120 to 240V, no manual switching required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging algorithm\u003c\/strong\u003e, fully automatic bulk, absorption and float stages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple outputs\u003c\/strong\u003e, three isolated outputs for simultaneous charging of separate battery banks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility\u003c\/strong\u003e, flooded, gel and AGM lead-acid chemistries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e, microprocessor-controlled with reverse polarity, short circuit and overheating protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow it charges\u003c\/h2\u003e\u003cp\u003eBulk charge delivers maximum current to bring the battery to around 80% capacity quickly. Absorption then holds voltage constant while current tapers off, completing the charge without overcharging. Float mode maintains full charge without gassing or electrolyte loss, useful where the charger stays connected for long periods.\u003c\/p\u003e\u003ch3\u003eTemperature compensation\u003c\/h3\u003e\u003cp\u003eWith an external battery temperature sensor connected, the charger adjusts charge voltage for battery temperature. This avoids undercharging in cold conditions and overcharging in hot ones, relevant for engine rooms or exposed enclosures.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to marine vessels with multiple battery banks such as starter, service, bow thruster or generator batteries. Also used in motorhomes and coaches for chassis and habitation batteries, off-grid cabins on generator or shore power, commercial vehicles with auxiliary systems, and industrial or telecoms backup power where batteries need continuous maintenance.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit by a qualified electrician or experienced marine or vehicle electrician familiar with DC battery systems. Fuse the AC supply correctly and use appropriately rated cable and fusing on the DC outputs for a 50A charge current. Mount in a ventilated location away from water ingress. Marine installs should follow relevant BMEA or RYA wiring guidance, and battery chemistry should be confirmed before selecting a charge profile.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eVictron Centaur Charger 12\/50(3) 120-240V unit\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52095617663264,"sku":"CCH012050000","price":371.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-cch012050000-1.webp?v=1785756634"}],"url":"https:\/\/www.ledandsolar.co.uk\/collections\/victron-skylla-centaur-battery-chargers.oembed?page=2","provider":"LED \u0026 Solar","version":"1.0","type":"link"}