{"title":"Victron Electric Vehicle (EV)","description":"\u003cp\u003eVictron EV charging stations handle AC wallbox charging with the option of tying into an existing solar PV and battery storage setup. The EV Charging Station NS supports dynamic load balancing and solar-boosted charging, so surplus solar power goes into the car instead of being exported to the grid.\u003c\/p\u003e\u003cp\u003eConnected to the Victron GX platform, charge sessions can be scheduled, monitored and adjusted remotely, making these units suitable for residential driveways as well as commercial car parks where smart energy management matters.\u003c\/p\u003e\u003cp\u003eThe range includes the standard charging station along with the NS model, which is available in blue and can be fitted with a black or white front panel to suit the installation.\u003c\/p\u003e","products":[{"product_id":"ev-charging-station-type-2","title":"Victron EV Charging Station Type 2 Solar Integration | EVC300400300","description":"\u003cp\u003eThe Victron Energy EV Charging Station is a single-phase EV charger built to work with Victron solar and battery systems. It suits residential and light commercial sites where solar self-consumption and smart charging control matter. Connect it to a Victron GX device and the charger becomes part of the wider Victron ecosystem, adjusting its charge rate in response to available solar or grid capacity.\u003c\/p\u003e\u003ch2\u003eVictron EV charging station features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntegrates with Victron GX devices for solar-aware and grid-aware EV charging control.\u003c\/li\u003e\n\u003cli\u003eSupports dynamic current adjustment, so the charge rate follows available solar or grid capacity.\u003c\/li\u003e\n\u003cli\u003eCompatible with all Type 2 (IEC 62196) electric vehicles, the standard connector across the UK and EU.\u003c\/li\u003e\n\u003cli\u003eCompact wall-mount design, 3 kg, suitable for indoor and sheltered outdoor installation.\u003c\/li\u003e\n\u003cli\u003eMonitored and controlled through the VictronConnect app and the Victron Remote Management (VRM) portal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSmart charging control\u003c\/h2\u003e\u003cp\u003eDynamic current control is the practical benefit of this charger. Rather than charging at a fixed rate, the station adjusts its output current based on rules configured through the GX device. That's useful on sites with export limits or where grid import costs need managing. The charger connects over a local network and shows up in VRM alongside the rest of the Victron system. Its Type 2 connector is the standard required for new EV charge points across the UK and EU, so it works with current passenger and light commercial vehicles.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolar self-consumption: charge an EV from surplus PV generation.\u003c\/li\u003e\n\u003cli\u003eOff-grid and hybrid systems where charge current needs to track battery state.\u003c\/li\u003e\n\u003cli\u003eResidential installations that need remote monitoring and control via VRM.\u003c\/li\u003e\n\u003cli\u003eLight commercial sites with existing Victron energy management equipment.\u003c\/li\u003e\n\u003cli\u003eSites with grid export limits that require dynamic load control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eInstallation must be carried out by a qualified electrician. In the UK, EV charge point installations fall under Part P of the Building Regulations and need notifying to the relevant building control authority. A Victron GX device is required for the smart charging features to work. Check that the supply circuit is rated for the unit's maximum charge current, and avoid fitting it anywhere exposed to direct weather without suitable enclosure protection.\u003c\/p\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x Victron Energy EV Charging Station (EVC300400300)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52060522086688,"sku":"EVC300400300","price":406.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-evc300400300-1.webp?v=1785491996"},{"product_id":"victron-ev-charging-station-black-front","title":"Victron Black Front Panel for EV Charging Station NS | EVC200300310","description":"\u003cp\u003eThis is the genuine replacement black front panel for the Victron EV Charging Station NS, a direct-fit cosmetic and protective cover for installers or owners who need to replace a damaged front or switch the colour of their existing NS unit.\u003c\/p\u003e\u003ch2\u003eKey features of the Victron EV Charging Station NS front panel\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitment\u003c\/strong\u003e, made specifically for the Victron Energy EV Charging Station NS, not compatible with other EV charger models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e, black, giving a plain appearance for domestic and commercial installs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit\u003c\/strong\u003e, direct replacement part, no modification needed to fit the NS housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 0.4 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine part\u003c\/strong\u003e, SKU EVC200300310, GTIN 8719076058496.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe front panel is the forward-facing cover of the NS charger unit. Panels can be damaged by impact, UV exposure or general wear over time. This genuine part restores the unit without needing a full charger replacement, and it is also the correct choice for anyone wanting a black finish rather than the standard colour.\u003c\/p\u003e\u003cp\u003eAs a genuine Victron component it matches the original tolerances and fixing points of the NS charging station. Installers carrying out warranty repairs or refurbishments should use genuine parts to keep the installation and any applicable warranty intact.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReplacing a cracked, scratched or damaged front panel on an existing Victron EV Charging Station NS.\u003c\/li\u003e\n\u003cli\u003eCosmetic refurbishment to restore the original appearance of an NS station.\u003c\/li\u003e\n\u003cli\u003eChanging from a non-black front panel to a black finish.\u003c\/li\u003e\n\u003cli\u003eSpares stock for EV charger installers and service engineers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x black front panel for Victron EV Charging Station NS\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cp\u003eFitting should be carried out by a qualified electrician or EV charger installer. Isolate the unit fully from the mains supply before removing or replacing any part. Do not fit the panel while the charger is energised. Where the installation is subject to UK OZEV or DNO requirements, record any maintenance work carried out.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52060750381344,"sku":"EVC200300310","price":26.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-evc200300310-1.webp?v=1785502811"},{"product_id":"ev-charging-station-ns-type2","title":"Victron EV Charging Station NS 22kW Type 2 Blue | EVC200300200","description":"\u003cp\u003eThe Victron EV Charging Station NS is a single-phase AC EV charger built for residential and light commercial use. It connects into Victron's GX ecosystem, so charging current can be adjusted automatically to prioritise solar self-consumption or stay within grid import limits.\u003c\/p\u003e\u003ch2\u003eVictron EV charging station NS key features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGX integration\u003c\/strong\u003e, compatible with Victron GX devices for dynamic power control and solar integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging standard\u003c\/strong\u003e, Mode 3 charging via a Type 2 (IEC 62196) connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable current\u003c\/strong\u003e, output current adjusts to match available solar generation or grid capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e, wall-mounted, blue enclosure suited to indoor and sheltered outdoor sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e, Modbus TCP, for integration with the VRM portal and Venus OS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 2.5 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct overview\u003c\/h2\u003e\u003cp\u003eThe GX control layer modulates the charger's output in real time based on excess PV production, battery state of charge, or grid import limits. That's useful in any system where the priority is using solar power on site rather than exporting it.\u003c\/p\u003e\u003cp\u003eNS denotes the non-smart version of Victron's EV charger range. There's no built-in display, but full network communication runs over Modbus TCP. Configuration and monitoring happen through a connected GX device or the VRM portal instead of a local touchscreen, which suits chargers mounted in a utility area with remote monitoring.\u003c\/p\u003e\u003cp\u003eThis blue-housed unit shares its electrical specification with the white variant. It is a wall-mounted fixture intended for fixed installation by a qualified electrician.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolar self-consumption EV charging, directing surplus PV generation to the vehicle rather than exporting it.\u003c\/li\u003e\n\u003cli\u003eResidential installations integrated with a Victron Multiplus or Quattro inverter\/charger system.\u003c\/li\u003e\n\u003cli\u003eOff-grid and hybrid systems that need dynamic charge current adjustment based on battery or generator capacity.\u003c\/li\u003e\n\u003cli\u003eLight commercial premises with a Victron GX device already managing energy flow.\u003c\/li\u003e\n\u003cli\u003eInstallations where remote monitoring via the VRM portal is preferred over a local display.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat's in the box\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1x Victron EV Charging Station NS (Blue)\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eThis unit must be installed by a qualified electrician in accordance with BS 7671 (IET Wiring Regulations) and any applicable local building regulations. A dedicated circuit with appropriate overcurrent and RCD protection is required. Integration with a Victron GX device needs an Ethernet connection at the installation point. If the installation connects to the public grid, confirm compliance with your Distribution Network Operator's requirements before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52060754051360,"sku":"EVC200300200","price":435.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-evc200300200-1.webp?v=1785503754"},{"product_id":"victron-ev-charging-station-ns-cover","title":"Victron White Front Cover for EV Charging Station NS | EVC200300410","description":"\u003cp\u003eA genuine white front cover for the Victron EV Charging Station NS, supplied as a spare or replacement part. It restores the factory appearance of the charger after damage, discolouration or a cover swap, without needing to replace the whole unit.\u003c\/p\u003e\u003ch2\u003eVictron EV Charging Station NS cover details\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit\u003c\/strong\u003e, direct replacement front cover for the Victron EV Charging Station NS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e, white, matching the standard factory appearance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e, 0.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number\u003c\/strong\u003e, SKU EVC200300410\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGTIN\u003c\/strong\u003e, 8719076058502\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFitted where a front cover on a Victron EV Charging Station NS has cracked, discoloured or needs swapping to a different colour variant. Installers and maintenance contractors also hold it as a spare part for callouts.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eThe cover itself is a cosmetic enclosure part and its fitting does not involve live electrical connections. The charging station it belongs to must only be installed, serviced or modified by a qualified electrician, in line with BS 7671 and relevant UK EV charging regulations. Isolate the supply before accessing any internal components.\u003c\/p\u003e\u003ch2\u003eWhat's included\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e1 x white front cover for Victron EV Charging Station NS\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52060756410656,"sku":"EVC200300410","price":26.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1010\/8148\/1504\/files\/ledandsolar-evc200300410-1.webp?v=1785504103"}],"url":"https:\/\/www.ledandsolar.co.uk\/collections\/victron-ev-charging-stations.oembed","provider":"LED \u0026 Solar","version":"1.0","type":"link"}